SDC Datasheet, PDF (1/4 Pages) XP Power Limited – High Power Density | |||
|
320 Watts
SDC Series
xppower.com
⢠High Power Density
⢠Single & Dual Outputs
⢠Up to 700 W Peak Power
⢠Fan Fail & Power Good Signals
⢠Low Leakage Current Option
⢠Fits 1U Applications
⢠3 Year Warranty
Specification
Input
Input Voltage
Input Frequency
Input Current
Inrush Current
Power Factor
Earth Leakage Current
Input Protection
⢠90-132 VAC/180-264 VAC, âAâ version,
90-264 VAC, âPâ version
⢠47-63 Hz
⢠7 A at 90 VAC, 3 A at 230 VAC, âAâ version
4.5 A at 90 VAC, 2 A at 230 VAC,
âPâ version
⢠Max 70 A at 230 VAC, 35 A at 115 VAC,
cold start
⢠EN61000-3-2 class A, âAâ version
>0.9 âPâ versions
⢠<500 µA at 264 VAC/50 Hz for âAâ version,
<1.5 mA at 264 VAC/50 Hz for âPâ version
(the option â-Lâ 500 µA is available for
P version)
⢠T8 A/250 V fuse, âAâ version
T6 A/250 V fuse, âPâ version
Output
Output Voltage
⢠See tables
Output Voltage Trim
⢠±5% on V1 (V2 of dual output models will
track by same % of adjustment)
Initial Set Accuracy ⢠±1%
Minimum Load
⢠1% on single output models,
10% on both output of dual output models
in order to maintain ripple & noise and
regulation specifications
Start Up Delay
⢠1.5 s max at 120 VAC
Start Up Rise Time
⢠50 ms typical
Hold Up Time
⢠20 ms min at 80% of full load
Line Regulation
⢠±0.5%
Load Regulation
⢠±1% 1-100% load for single outputs,
±3% V1, ±7% V2 for dual outputs
(except AD0548 version: ±11% on V2)
Over/Undershoot
⢠5% max
Transient Response
⢠±5% max deviation, recovery to within
1% in 500 µs for a 50% load change
Ripple & Noise
⢠1% pk-pk (see note 3)
Overvoltage Protection ⢠<130% on V1 recycle AC input to reset
Overtemperature
⢠Measured internally auto recovery
Overload Protection ⢠110-140%
Short Circuit Protection ⢠Trip & restart, auto recovery
Fan Supply
⢠12 V/300 mA, not available on
â-Fâ & â-Eâ versions with built-in fans
Remote On / Off
⢠Fitted to âPâ version only
General
Efficiency
Isolation
Switching Frequency
Power Density
Signals
MTBF
⢠Single output: 5 V: 70%,12 V: 80%,
All other models: >83% at 230 V & full load,
Dual Output: >70% at 230 V & full load
⢠3000 VAC Input to Output, 1500 VAC
Input to Ground, 250 VDC Output to
Ground
⢠23 kHz typical single output models,
25 kHz typical dual output models
âAâ versions,
60 kHz PFC, 56 kHz PWM âPâ versions
⢠8.9 W/In3
⢠Fan Fail & Power Good
⢠>100 kHrs to MIL-HDBK-217F,
at 25 °C GB
Environmental
Operating Temperature ⢠0 °C to +70 °C, derate at 2.5%/°C from
+50 °C to +70 °C when force air cooled.
0 °C to +60 °C, derate at 5%/°C from
+50 °C to +60 °C when convection cooled.
Storage Temperature ⢠-20 °C to +85 °C
Operating Humidity ⢠5-90%, non-condensing
Cooling
⢠â-Fâ & â-Eâ versions have built-in fans, 5 V
single output model requires 22 CFM to
meet forced air ratings, all other models
require 18 CFM. âPâ version requires
27 CFM on all models
Operating Altitude
⢠3000 m
Vibration
⢠5-50 Hz, acceleration 7.35 ms2 on 3 axes
EMC & Safety
Emissions
Harmonic Currents
Voltage Flicker
ESD Immunity
Radiated Immunity
EFT/Burst
Surge
Conducted Immunity
Dips & Interruptions
Safety Approvals
⢠EN55022 Level B conducted & radiated
⢠EN61000-3-2 class A
EN61000-3-2 class C for loads â¥30%
(âPâ versions only)
⢠EN61000-3-3
⢠EN61000-4-2, level 3 Perf Criteria A
⢠EN61000-4-3, 3 V/m Perf Criteria A
⢠EN61000-4-4, level 2 Perf Criteria A
⢠EN61000-4-5, installation class 3
Perf Criteria A
⢠EN61000-4-6, 3V Perf Criteria A
⢠EN61000-4-11, 30% 10 ms, 60% 100 ms,
100% 5000 ms Perf Criteria A, B, B
⢠UL60950-1, CSA C22.2 No. 60950-1,
EN60950-1
|
▷ |