English
Language : 

SDC Datasheet, PDF (1/4 Pages) XP Power Limited – High Power Density
320 Watts
SDC Series
xppower.com
• High Power Density
• Single & Dual Outputs
• Up to 700 W Peak Power
• Fan Fail & Power Good Signals
• Low Leakage Current Option
• Fits 1U Applications
• 3 Year Warranty
Specification
Input
Input Voltage
Input Frequency
Input Current
Inrush Current
Power Factor
Earth Leakage Current
Input Protection
• 90-132 VAC/180-264 VAC, ‘A’ version,
90-264 VAC, ‘P’ version
• 47-63 Hz
• 7 A at 90 VAC, 3 A at 230 VAC, ‘A’ version
4.5 A at 90 VAC, 2 A at 230 VAC,
‘P’ version
• Max 70 A at 230 VAC, 35 A at 115 VAC,
cold start
• EN61000-3-2 class A, ‘A’ version
>0.9 ‘P’ versions
• <500 µA at 264 VAC/50 Hz for ‘A’ version,
<1.5 mA at 264 VAC/50 Hz for ‘P’ version
(the option ‘-L’ 500 µA is available for
P version)
• T8 A/250 V fuse, ‘A’ version
T6 A/250 V fuse, ‘P’ version
Output
Output Voltage
• See tables
Output Voltage Trim
• ±5% on V1 (V2 of dual output models will
track by same % of adjustment)
Initial Set Accuracy • ±1%
Minimum Load
• 1% on single output models,
10% on both output of dual output models
in order to maintain ripple & noise and
regulation specifications
Start Up Delay
• 1.5 s max at 120 VAC
Start Up Rise Time
• 50 ms typical
Hold Up Time
• 20 ms min at 80% of full load
Line Regulation
• ±0.5%
Load Regulation
• ±1% 1-100% load for single outputs,
±3% V1, ±7% V2 for dual outputs
(except AD0548 version: ±11% on V2)
Over/Undershoot
• 5% max
Transient Response
• ±5% max deviation, recovery to within
1% in 500 µs for a 50% load change
Ripple & Noise
• 1% pk-pk (see note 3)
Overvoltage Protection • <130% on V1 recycle AC input to reset
Overtemperature
• Measured internally auto recovery
Overload Protection • 110-140%
Short Circuit Protection • Trip & restart, auto recovery
Fan Supply
• 12 V/300 mA, not available on
‘-F’ & ‘-E’ versions with built-in fans
Remote On / Off
• Fitted to ‘P’ version only
General
Efficiency
Isolation
Switching Frequency
Power Density
Signals
MTBF
• Single output: 5 V: 70%,12 V: 80%,
All other models: >83% at 230 V & full load,
Dual Output: >70% at 230 V & full load
• 3000 VAC Input to Output, 1500 VAC
Input to Ground, 250 VDC Output to
Ground
• 23 kHz typical single output models,
25 kHz typical dual output models
‘A’ versions,
60 kHz PFC, 56 kHz PWM ‘P’ versions
• 8.9 W/In3
• Fan Fail & Power Good
• >100 kHrs to MIL-HDBK-217F,
at 25 °C GB
Environmental
Operating Temperature • 0 °C to +70 °C, derate at 2.5%/°C from
+50 °C to +70 °C when force air cooled.
0 °C to +60 °C, derate at 5%/°C from
+50 °C to +60 °C when convection cooled.
Storage Temperature • -20 °C to +85 °C
Operating Humidity • 5-90%, non-condensing
Cooling
• ‘-F’ & ‘-E’ versions have built-in fans, 5 V
single output model requires 22 CFM to
meet forced air ratings, all other models
require 18 CFM. ‘P’ version requires
27 CFM on all models
Operating Altitude
• 3000 m
Vibration
• 5-50 Hz, acceleration 7.35 ms2 on 3 axes
EMC & Safety
Emissions
Harmonic Currents
Voltage Flicker
ESD Immunity
Radiated Immunity
EFT/Burst
Surge
Conducted Immunity
Dips & Interruptions
Safety Approvals
• EN55022 Level B conducted & radiated
• EN61000-3-2 class A
EN61000-3-2 class C for loads ≥30%
(‘P’ versions only)
• EN61000-3-3
• EN61000-4-2, level 3 Perf Criteria A
• EN61000-4-3, 3 V/m Perf Criteria A
• EN61000-4-4, level 2 Perf Criteria A
• EN61000-4-5, installation class 3
Perf Criteria A
• EN61000-4-6, 3V Perf Criteria A
• EN61000-4-11, 30% 10 ms, 60% 100 ms,
100% 5000 ms Perf Criteria A, B, B
• UL60950-1, CSA C22.2 No. 60950-1,
EN60950-1