RCL175PS12 Datasheet, PDF (1/4 Pages) XP Power Limited – AC-DC Power Supplies | |||
|
175 Watts
RCL175 Series
xppower.com
⢠200 W Peak Rating
⢠Up to 120 W Convection-cooled
⢠Industrial and Medical Approvals
⢠Low Leakage Current
⢠Class I & Class II Applications
⢠Flexible Design for Modified Standards
⢠Connector & Mechanical Options
Specification
Input
Input Voltage
⢠85-264 VAC (120-370 VDC) See note 3
Input Frequency
⢠47-63 Hz
Input Current
⢠2.1 A max at 115 VAC
0.9 A max at 230 VAC
Inrush Current
⢠17 A max at 115 VAC, 35 A max at
230 VAC, cold start at +25 °C
Power Factor
⢠Complies with EN61000-3-2 for
Class A equipment
Earth Leakage Current ⢠120 µA max at 115 VAC
200 µA max at 230 VAC
Input Protection
⢠3.15 A line and neutral fused
Output
Output Voltage
⢠See models and ratings table
Output Voltage Trim
⢠±10% output 1 via pot, outputs 2-4 track
by same percentage
Initial Set Accuracy ⢠±2% of nominal at 50% load
Minimum Load
⢠See models & ratings table
Start Up Delay
⢠<2 s
Start Up Rise Time
⢠<100 ms
Hold Up Time
⢠20 ms min at nominal low line
& maximum power
Drift
⢠<±0.2% after 20 mins warm up
Line Regulation
⢠±0.5% of nominal over full input range
Load Regulation
⢠PQ42 & 43: V1 & V2 ±3%, V3 & V4 ±5% of
nominal, all other models: V1 ±1%, V2, V3
& V4 ±5% of nominal
Transient Response
⢠4% max deviation, recovery to within 1%
in 500 µs for a 25% load change at 1 A/µs
Ripple & Noise
⢠50 mV (Vo=<5 V), 120mV (Vo=12, 15 V),
200 mV (Vo=24, 48 V). Measured pk-pk
with a 20 MHz bandwidth
Overvoltage Protection ⢠115-140% - V1 only. Cycle mains to reset
Overtemperature
Protection
⢠Fitted with auto restart
Overload Protection
⢠110-125% - Primary side power limiting
with auto recovery. Constant current limit
for single output models and foldback
current limit for multi output models.
V3 & V4 PTC resetting fuses
Temperature
Coefficient
⢠0.02%/°C
General
Efficiency
Isolation
Switching Frequency
Signals
Remote Sense
Remote On/Off
MTBF
⢠80-90% depending on model
⢠4000 VAC Input to Output
1500 VAC Input to Ground
1500 VAC Output to Ground open frame
(For BF applications, consult sales office)
500 VAC Output to Ground U channel
& covered
⢠PFC 75 kHz typical, PWM 60 kHz typical
⢠Power fail - open collector output
referenced to 0 V sense
⢠See Application Notes
⢠See Application Notes
⢠385 kHrs typical at +25 °C per
MIL-HDBK-217F
Environmental
Operating Temperature ⢠-10 °C to +50 °C at full power, derate to
50% power at +70 °C
Operating Humidity ⢠5-95% RH, non-condensing
Storage Temperature ⢠-20 °C to +85 °C
Operating Altitude
⢠3000m
Shock
⢠30 g peak, half sine, 6 axes
Vibration
⢠2 g rms, 5-500 Hz, 3 axes
EMC & Safety
Emissions
Harmonic Currents
Voltage Flicker
ESD Immunity
Radiated Immunity
EFT/Burst
Surge
Conducted Immunity
Dips & Interruptions
Safety Approvals
⢠EN55011/22 class B conducted,
class A radiated
⢠EN61000-3-2 for class A equipment
⢠EN61000-3-3
⢠EN61000-4-2, Level 3 Perf Criteria A
⢠EN61000-4-3, 10 V rms 80% mod,
Perf Criteria A
⢠EN61000-4-4, Level 3 Perf Criteria A
⢠EN61000-4-5, Level 3 Perf Criteria A
⢠EN61000-4-6, Level 3 Perf Criteria A
⢠EN61000-4-11, 30% 10 ms,
60% 100 ms, 100% 5000 ms,
Perf Criteria A, B, B
⢠EN60601-1-1, EN60950-1:2001,
UL/cUL60950:2003, CSA60601.1,
UL60601-1:2003.
|
▷ |