English
Language : 

PQ-100B Datasheet, PDF (1/3 Pages) XP Power Limited – 100W Quad Output Switching Power Supply
100W Quad Output Switching Power Supply
PQ-100 series
Features :
Universal AC input / Full range
Protections:Short circuit/Over load/Over voltage
Cooling by free air convection
With power good signal output(Optional)
100% full load burn-in test
Fixed switching frequency at 45KHz
2 years warranty
SPECIFICATION
MODEL
PQ-100B
PQ-100C
OUTPUT NUMBER
CH1
CH2
CH3
CH4
CH1
CH2
CH3
CH4
DC VOLTAGE
5V
12V
-5V
-12V
5V
15V
-5V
-15V
RATED CURRENT
10A
3.5A
0.5A
0.5A
8A
3.5A
0.5A
0.5A
CURRENT RANGE
2 ~ 10A
0.5 ~ 4.5A 0 ~ 1A
0 ~ 1A
2 ~ 8A
0.5 ~ 4A
0 ~ 1A
0 ~ 1A
OUTPUT
RATED POWER
100.5W
RIPPLE & NOISE (max.) Note.2 80mVp-p
250mVp-p
VOLTAGE ADJ. RANGE
CH1:4.75 ~ 5.5V
VOLTAGE TOLERANCE Note.3 3.0%
12%
LINE REGULATION
1.0%
5.0%
80mVp-p
6.0%
1.0%
120mVp-p
6.0%
1.0%
102.5W
80mVp-p
150mVp-p
CH1:4.75 ~ 5.5V
2.0%
6.0%
1.0%
3.0%
80mVp-p
6.0%
1.0%
150mVp-p
6.0%
1.0%
LOAD REGULATION
2.0%
5.0%
1.0%
1.0%
1.0%
5.0%
1.0%
1.0%
SETUP, RISE TIME
1200ms, 50ms at full load
HOLD TIME (Typ.)
80ms at full load
VOLTAGE RANGE
100 ~ 264VAC 141 ~370VDC (90 ~ 100VAC 90% load max.)
FREQUENCY RANGE
47 ~ 63Hz
INPUT
EFFICIENCY(Typ.)
72%
74%
AC CURRENT (Typ.)
3A/115VAC 1.5A/230VAC
INRUSH CURRENT (Typ.) COLD START 50A
LEAKAGE CURRENT
<1mA /240VAC
OVER LOAD
PROTECTION
OVER VOLTAGE
FUNCTION POWER GOOD
WORKING TEMP.
WORKING HUMIDITY
ENVIRONMENT STORAGE TEMP., HUMIDITY
TEMP. COEFFICIENT
VIBRATION
SAFETY STANDARDS
WITHSTAND VOLTAGE
105% ~ 135% rated output power
Protection type : Hiccup mode, recovers automatically after fault condition is removed
CH1: 5.75 ~ 6.75VDC
Protection type : Hiccup mode, recovers automatically after fault condition is removed
1ms
-10 ~ +50 ,60 with cooling fan(Refer to output load derating curve)
20 ~ 90% RH non-condensing
-20 ~ +85 , 10 ~ 95% RH
0.03%/ (0 ~ 50 )
10 ~ 500Hz, 2G 10min./1cycle, Period for 60min.each along X, Y, Z axes
UL60950-1, TUV EN60950-1 Approved
I/P-O/P:3KVAC I/P-FG:1.5KVAC O/P-FG:0.5KVAC
SAFETY & ISOLATION RESISTANCE I/P-O/P, I/P-FG, O/P-FG:100M Ohms/500VDC
EMC
(Note 4)
EMI CONDUCTION & RADIATION Compliance to EN55022 (CISPR22) Class B
HARMONIC CURRENT
Compliance to EN61000-3-2,-3
OTHERS
NOTE
EMS IMMUNITY
Compliance to EN61000-4-2,3,4,5,6,11; ENV50204, Light industry level, criteria A
MTBF
258.6K hrs min. MIL-HDBK-217F (25 )
DIMENSION
177.8*107.95*46mm (L*W*H)
PACKING
0.56Kg; 24pcs/14.5Kg/1.19CUFT
1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 of ambient temperature.
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
3. Tolerance : includes set up tolerance, line regulation and load regulation.
4. The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets
EMC directives.
File Name:PQ-100-SPEC 2006-02-14