MTC0528S3V3 Datasheet, PDF (1/4 Pages) XP Power Limited – DC-DC Power Supplies | |||
|
5-35 Watts
MTC Series
xppower.com
⢠10-50 VDC Input Range
⢠Designed for Vetronic & Avionic Use
⢠Single & Dual Output Versions
⢠-55 °C Operation Available
⢠EMI Performance to MIL-STD 461E/F
⢠Input Immunity to MIL-STD 1275A/B/C/D
⢠Environments to MIL-STD 810F
Specification
Input
Input Voltage Range
Transient Input Range
Turn On
Turn Off
Input Reverse Voltage
Protection
Max Input Current
⢠15.5-40.0 VDC
⢠10 VDC maximum load for 10 s,
50 VDC for 1 s at full load
⢠<15.5 VDC
⢠<10 VDC
⢠None
⢠See table
Output
Output Voltage
⢠See table
Output Voltage Trim ⢠See table (Not available for dual outputs)
Minimum Load
⢠No minimum load required
Line Regulation
⢠±1% Vout nominal (15.5-40.0 Vin)
Load Regulation
⢠±1% Vout nominal
Cross Regulation
⢠±3% with 150 mA min load
(Dual output only) see longform datasheet
for more information
Output Set Tolerance ⢠±100 mV or ±2% whichever is greater
Ripple & Noise
⢠â¤5 Vout: 60 mV pk-pk max,
>5 Vout: 1% pk-pk, at max load
& 20 MHz BW
Overvoltage Protection ⢠110-120% Vout max
(15 W & 30 W versions only)
Overcurrent Protection ⢠105-150% at nominal input voltage
Overtemperature
Protection
⢠102 °C to 107 °C,
2 °C to 5 °C hysteresis
Remote Sense
⢠0.5 V (Single output only)
Load Step Output
Transient
⢠<±3% of Vout nom (25-75% load)
Load Step Recovery ⢠500 µs within 1% of nominal value
Line Step Output
Transient
⢠<±3% of nominal Vout (15.5-40.0 Vin)
Line Step Recovery ⢠500 µs within 1% of nominal value
Start Up Time
⢠<100 ms
Maximum Capacitive ⢠300 µF x Iout max startup within 100 ms
Load
General
Efficiency
Isolation
Switching Frequency
Frequency
Synchronisation
Inhibit
MTBF
⢠See tables and performance curves
⢠1500 VDC Input to Output, 1000 VDC
Input to Case, 500 VDC Output to Case
⢠Fixed 450 kHz typical
⢠400-500 kHz
⢠Off = TTL Low or short circuit
On = TTL High or open circuit
⢠MTC05: 1.7 MHrs, MTC15: 890 kHrs
MTC30: 740 kHrs, to MIL-HDBK-217F GF
at +40 °C
Environmental
Case Temperature
Operating Humidity
Storage Temperature
Operating Altitude
Shock
Vibration
Bump
Salt Atmosphere
⢠-40 °C to +100 °C
(extended range â-LTâ: -55 °C to +100 °C)
⢠88% Relative Humidity
240h MIL-STD-810D Method 507.2
⢠-50 °C to + 125 °C
⢠Tested to 70000 ft (21336 m)
⢠100 g MIL-STD-810D Method 516.3
⢠10 to 2000 Hz MIL-STD-810D
Method 514.3
⢠2000 Bumps in each axis 40 g
MIL-STD-810D Method 516.3
⢠48 hours MIL-STD-810E Method 509.3
Environmental Screening
& Low Temperature
All standard products are stress-screened and electrically tested over
the operating temperature range. See notes for option details.
EMC
Conducted Emissions
Immunity
Conducted
Susceptibilty
⢠EN55022 Conducted Level B*
MIL-STD 461E/F CE102*
DEF STAN 59-41: DCE01/DCE02*
⢠MIL-STD-704 A*, MIL-STD-704 B-F
MIL-STD-1275A/B/C/D*
⢠MIL-STD-461E/F CS101
CS114,CS115,CS116*
* MTF50 Filter Module recommended to meet these standards
|
▷ |