MQP12028S3V3 Datasheet, PDF (1/6 Pages) XP Power Limited – DC-DC Power Supplies | |||
|
120 Watts
MQP Series
xppower.com
⢠9.5 VDC to 40 VDC Input
⢠MIL-STD-461E Compliance
⢠Isolated Output
⢠Regulated Output
⢠Continuous Short Circuit Protection
⢠Five-Sided Metal Case
⢠Rugged Construction
Specification
Input
Input Voltage Range
Input Current
Input Transient
Undervoltage Lockout
Protection
⢠9.5-40 VDC
⢠See models & ratings table
⢠MIL-STD-1275A-D, MIL-STD-704A when
used in conjuction with DSF200/DSF500
filter module (see application notes)
⢠9.0-9.1 VDC
Output
Output Voltage
⢠See models & ratings table
Output Voltage
Adjustment
⢠70-110%
Minimum Load
⢠No minimum load required
Line Regulation
⢠±0.6%
Load Regulation
⢠±0.6%, 10-100% load
Turn-on Time
⢠Typically 100 ms
Ripple & Noise
⢠3%, 20 MHz BW
Overvoltage Protection ⢠120% typical
Overcurrent Protection ⢠108-115% (see application notes)
Short Circuit Protection ⢠Continuous
Overtemperature
Protection
⢠+101°C to +107 °C case temperature
Current Share
⢠Max 4 modules, derate total output current
to 90% (see application notes)
General
Efficiency
Isolation Voltage
Switching Frequency
Power Density
Package Style
MTBF
⢠See model & ratings table
⢠3000 VAC Input to Output
1500 VAC Input to Case
1500 VAC Output to Case
⢠Typically 300 kHz
⢠Up to 26.7 W/In3
⢠Baseplate cooled
⢠1 MHrs +25 °C
Environmental
Operating Temperature ⢠-40 °C to +85 °C
Storage Temperature ⢠-50 °C to +125 °C
Case Temperature
⢠+100 °C max, thermal resistance case
to ambient (θCA) 5.5 °C/W
Shock
Vibration
⢠EN61373 Category 1, Class B
⢠EN61373 Category 1, Class B
EMC & Safety
Conducted Emissions
Conducted
Susceptibility
Immunity
⢠MIL-STD-461E with external components
(see application notes)
⢠MIL-STD-461E CS101, CS114, CS115,
CS116 with DSF200LV filter
(see application notes)
⢠MIL-STD-1275A-D with DSF200LV filter
(see application notes)
|
▷ |