MP300-2400 Datasheet, PDF (1/6 Pages) XP Power Limited – Fully Featured Signal Set | |||
|
300-2400 Watts
MP Series
xppower.com
⢠Configurable for Fast Time to Market
⢠1 to 24 Outputs
⢠Floating Outputs
⢠Fully Featured Signal Set
⢠SEMI F47 Compliant
⢠Extra Power Available at High Line
⢠3 Year Warranty
Specification
Input
Input Voltage
Input Frequency
Inrush Current
Power Factor
Earth Leakage Current
Input Protection
⢠90-264 VAC
⢠47-63 Hz
⢠40 A max at 230 VAC, cold start 25 °C
⢠Compliant with EN61000-3-2, Class A
⢠<1.5 mA
⢠F3/FF: Internal T6.3 A/250 V fuse in line
F4/F6: Internal T10 A/250 V fuse in line
F7: Internal T12 A/250 V fuse in line
F8: Internal T15 A/250 V fuse in line
FX: Internal T20 A/250 V fuse in line
Output
Output Voltage
⢠See module table
Output Voltage Trim ⢠±5% typical all outputs
Hold Up Time
⢠20 ms min
Line Regulation
⢠Typically 0.1%, maximum 0.3%
Load Regulation
⢠1% max for single output modules
& V1 of dual & triple output modules.
2% max for V2 & V3 of dual & triple
output modules. The E module requires
up to 10% load & the K module up to 5%
load on V1 to achieve the specified
regulation figures on V2 & V3
Ripple & Noise
⢠50 mV or 1% pk-pk, whichever is greater,
20 MHz bandwidth
Overvoltage Protection ⢠115-130% Vnom for single output and out-
put 1 of dual & triple output modules. No
OVP fitted to G modules or H modules.
Overload Protection ⢠<150% of nominal rating
Short Circuit Protection ⢠Continuous trip & restart (Hiccup mode)
Temperature
Coefficient
⢠0.03%/°C
Remote Sense
⢠See signals & controls page
Current Share
⢠Single wire parallel current share.
See signals & controls page
Inhibit
⢠TTL compatible.
See signals & controls page
General
Efficiency
Isolation
Signals & Controls
MTBF
⢠75% typical at nominal input
⢠3000 VAC Input to Output
1500 VAC Input to Ground
500 VAC Output to Ground
⢠AC OK, DC OK, Current share, Global
Inhibit, Module Inhibit, Remote Sense,
Voltage Programming & 5V Standby
⢠750 kHrs Demonstrated
Environmental
Operating Temperature ⢠0 °C to +70 °C, derate linearly from 100%
at +50 °C to 50% at +70 °C for standard
models. Derate linearly from 100% at
+40 °C to 50% at +60 °C for reverse
air models.
Storage Temperature ⢠-40 °C to +85 °C
Operating Altitude
⢠3000 m
Shock
⢠30 g, 11 ms (half sine), 3 shocks each axis,
18 shocks total. Compliant with EN60068-
2-27
Vibration
⢠2 g, 10-500 Hz, 10 sweeps 3 axes.
Compliant with EN60068-2-6
EMC & Safety
Emissions
Harmonic Currents
Voltage Flicker
ESD Immunity
Radiated Immunity
EFT/Burst
Surge
Conducted Immunity
Dips & Interruptions
Safety Approvals
⢠EN55022, level B conducted
⢠EN61000-3-2, Class A
⢠EN61000-3-3
⢠EN61000-4-2, level 3 Perf Criteria A
⢠EN61000-4-3, level 3 Perf Criteria A
⢠EN61000-4-4, level 3 Perf Criteria A
⢠EN61000-4-5, level 3 Perf Criteria A
⢠EN61000-4-6, level 3 Perf Criteria A
⢠EN61000-4-11, 30% 10 ms,
60% 100 ms, 100% 5000 ms,
Perf Criteria A, B, B
⢠EN60950, UL60950, CSA22.2-No 950
CE Mark LVD, SEMI F47 compliant (high
line only)
|
▷ |