Specification
Input
Input Voltage
Input Frequency
Inrush Current
Input Protection
• 90-264 VAC (120-370 VDC)
• 47-63 Hz
• 40 A max at 230 VAC, cold start 25 ºC
• Internally fused
Output
(Specification rated at Ta = 25 ºC & 100 % load unless specified otherwise)
Output Voltage
• 12 to 28 VDC
(for other output voltages 3.3 V to 48 V -
please consult technical sales)
Initial Set Accuracy • ±1.0%
Minimum Load
• No minimum load required
Start Up Delay
• 2 s max
Start Up Rise Time
• 50 ms
Hold Up Time
• 16/75 ms minimum at 115/230 VAC
Line Regulation
• ±0.5%
Load Regulation
• ±1%
Over/Undershoot
• None at turn on/off
Transient Response
• 4% max. deviation, recovery to within
1% in 500 µs for a 25% load change
Ripple & Noise
• 1% pk-pk, 20MHz BW with 1 µF capacitor
connected across measurement points
Overvoltage Protection • 115-135% Vnom, recycle input to reset
Overload Protection
• 110-150%, on primary power limit,
auto recovery
Short Circuit Protection • Trip and restart (Hiccup mode)
Temperature
Coefficient
• 0.05% /ºC
General
Efficiency
Isolation
Switching Frequency
MTBF
• 80-85%
• 4000 VAC Input to Output
1500 VAC Input to Ground
500 VAC Output to Ground
• 70 kHz typical
• 250 kHrs per MIL-HDBK-217F
Environmental
Operating Temperature • -40 ºC to +70 ºC, derate linearly from
100% load at +50 ºC to 50% load
at +70 ºC. Start up at -30 ºC.
Cooling
• Convection-cooled
Operating Humidity • 95% RH, non-condensing
Storage Temperature • -40 ºC to + 85 ºC
Shock
• 30 g pk, half sine, 6 axes
Vibration
• 2 g rms, 5 Hz to 500 kHz, 3 axis
EMC & Safety
Emissions
EMI Immunity
Safety Approvals
• MIL-STD-461E, CE102, RE102
• MIL-STD 461E, CS101, 114, 115,
116 & RS103
• Designed to meet EN60950, UL60950
Mechanical
AC Input Connector
DC Output Connector
• AC mains lead, for UK or European mains
lead contact technical sales.
• D-Sub Type. For customer specfic options
please contact sales.