MCM60US12-D9 Datasheet, PDF (1/2 Pages) XP Power Limited – AC-DC Power Supplies | |||
|
60 Watts
MCM Series
xppower.com
⢠Compact Size - High Power Density
⢠Rugged Construction
⢠Universal Input
⢠Wide Operating Temperature
⢠EMI Performance to MIL-STD-461E
⢠Convection-cooled
⢠Manufactured in the USA
Specification
Input
Input Voltage
Input Frequency
Inrush Current
Input Protection
⢠90-264 VAC (120-370 VDC)
⢠47-63 Hz
⢠40 A max at 230 VAC, cold start 25 ºC
⢠Internally fused
Output
(Specification rated at Ta = 25 ºC & 100 % load unless specified otherwise)
Output Voltage
⢠12 to 28 VDC
(for other output voltages 3.3 V to 48 V -
please consult technical sales)
Initial Set Accuracy ⢠±1.0%
Minimum Load
⢠No minimum load required
Start Up Delay
⢠2 s max
Start Up Rise Time
⢠50 ms
Hold Up Time
⢠16/75 ms minimum at 115/230 VAC
Line Regulation
⢠±0.5%
Load Regulation
⢠±1%
Over/Undershoot
⢠None at turn on/off
Transient Response
⢠4% max. deviation, recovery to within
1% in 500 µs for a 25% load change
Ripple & Noise
⢠1% pk-pk, 20MHz BW with 1 µF capacitor
connected across measurement points
Overvoltage Protection ⢠115-135% Vnom, recycle input to reset
Overload Protection
⢠110-150%, on primary power limit,
auto recovery
Short Circuit Protection ⢠Trip and restart (Hiccup mode)
Temperature
Coefficient
⢠0.05% /ºC
General
Efficiency
Isolation
Switching Frequency
MTBF
⢠80-85%
⢠4000 VAC Input to Output
1500 VAC Input to Ground
500 VAC Output to Ground
⢠70 kHz typical
⢠250 kHrs per MIL-HDBK-217F
Environmental
Operating Temperature ⢠-40 ºC to +70 ºC, derate linearly from
100% load at +50 ºC to 50% load
at +70 ºC. Start up at -30 ºC.
Cooling
⢠Convection-cooled
Operating Humidity ⢠95% RH, non-condensing
Storage Temperature ⢠-40 ºC to + 85 ºC
Shock
⢠30 g pk, half sine, 6 axes
Vibration
⢠2 g rms, 5 Hz to 500 kHz, 3 axis
EMC & Safety
Emissions
EMI Immunity
Safety Approvals
⢠MIL-STD-461E, CE102, RE102
⢠MIL-STD 461E, CS101, 114, 115,
116 & RS103
⢠Designed to meet EN60950, UL60950
Mechanical
AC Input Connector
DC Output Connector
⢠AC mains lead, for UK or European mains
lead contact technical sales.
⢠D-Sub Type. For customer specfic options
please contact sales.
|
▷ |