MCC400-600 Datasheet, PDF (1/2 Pages) XP Power Limited – Baseplatecooled | |||
|
400/600 Watts
MCC Series
xppower.com
⢠Baseplate cooled
⢠Up to 4 Regulated Outputs
⢠Optional 200 W Conditioned Output
⢠MIL STD 1275 and DEF STAN 61 5
⢠MIL STD 461 and DEF STAN 59 411
⢠Rugged Construction to MIL STD 810F
⢠3 Year Warranty
Specification
Input
Input Voltage Range
Input Current
Inrush Current
Input Reverse Voltage
Protection
Input Transient
Undervoltage Lockout
⢠18.5-34 VDC steady state
⢠27 A at 18.5 V max
⢠<60 A
⢠Continuous
⢠MIL-STD-1275A/B/C/D
⢠Vin <18 VDC
Output
Output Voltage
⢠O/P 1-4: regulated outputs 2-48 VDC
Output Voltage
Adjustment
⢠O/P 1-4: 10-110% factory set
A minimum load of 10% is required for
outputs below 90% of nominal voltage
Optional Aux.
Output Rail Voltage
⢠Vin - 2 VDC(1)
Optional Aux.
Output Power
⢠200 W for MCC600 (9 A max)
Maximum Aux. Output ⢠Vout clamped <36 VDC
Minimum Load
⢠No minimum load (output ripple increased
at Pout <10% Pout max)
Line Regulation
⢠1% max
Load Regulation
⢠1% max
Cross Regulation
⢠Outputs 1-4 individually regulated,
no cross regulation
Output Set Tolerance ⢠±100 mV
External Hold Up
⢠External connection for additional hold up
capacitance, see longform datasheet
Ripple & Noise
⢠50 mV or 1% pk-pk, whichever is the
greater, 20 MHz bandwidth
Low Noise (Option âQâ ) ⢠Outputs 1 & 2: 25 mV reduction
Outputs 3 & 4: 45 mV reduction
Temperature Coefficient ⢠±0.05%/ËC
Overvoltage Protection ⢠110-120% of nominal output,
recycle input to restart
Overcurrent Protection ⢠110-120% of nominal output,
auto recovery
Short Circuit Protection ⢠Continuous, with auto restart
Overtemperature
Protection
⢠>+90 ËC baseplate temperature,
auto restart
Remote Sense
⢠Outputs 1 & 2, Compensate for 0.5 V total
voltage drop
General
Efficiency
Isolation Voltage
Material and Finish
Input Inhibit
Output Inhibit
Inhibited Input Current
DC OK Signal
MTBF
⢠75% typical
⢠500 VDC Input to Output,
500 VDC Output to Chassis,
500 VDC Input to Chassis
⢠Aluminium baseplate and safety cover
⢠Global enable and disable function,
short to negative input to inhibit
⢠Each regulated output has independent
inhibit, TTL high to inhibit
⢠<5 mA when input inhibit function is used
⢠Optional on output voltages â¥5 VDC
Isolated opto-coupler transistor output
⢠517 kHrs to MIL-HDBK-217F at 40 ËC, GB
Environmental
Operating Temperature ⢠-40 ËC to +70 ËC ambient with baseplate
temperature within -40 ËC to +90 ËC
Extended Temperature ⢠-55 ËC to +90 ËC baseplate temperature,
(see note 4)
Cooling
⢠Baseplate-cooled. It is recommended
that a thermal pad or compound is
fitted between the MCC baseplate and
any heatsink
Operating Humidity ⢠20-95% non-condensing
Storage Temperature ⢠-55 ËC to +90 ËC
Storage Humidity
⢠20-95% non-condensing
Shock
⢠40 g MIL-STD-810F, method 516.5-1
Vibration
⢠MIL-STD-810F, method 514.5C-17
minimum integrity test for military
equipment
EMC
Emissions
Conducted Immunity
⢠EN55022 Level B conducted
MIL-STD-461E/F army ground use
CE101 & CE102
DEF-STAN 59-411, DCE01/DCE02
⢠MIL-STD-1275A/B/C/D,
MIL-STD-461E/F
CS101, CS114, CS115, CS116
DEF-STAN 61-5 part 6 issue 5
(1) Vin - 2VDC minimum 36 VDC (clamped) maximum
|
▷ |