LCL150 Datasheet, PDF (1/4 Pages) XP Power Limited – 150-500 Watts LCL Series | |||
|
150 500 Watts
LCL Series
xppower.com
⢠Single Output Industrial Supplies
⢠High Efficiency
⢠Low Cost
⢠150 W Convection Cooled
⢠300 W & 500 W with Internal Fans
⢠Outputs from 12 V to 48 V
⢠3 Year Warranty
Specification
Input
Input Voltage
Input Frequency
Input Current
Inrush Current
Power Factor
Earth Leakage Current
Input Protection
⢠85-264 VAC (127-370 VDC) (see note 1)
⢠47-63 Hz
⢠2.1 A max for LCL150, 4.5 A max for
LCL300, 6.6 A max for LCL500
⢠40 A max for LCL150,
60 A max for LCL300 & 500
cold start at 25 ÅC, 230 VAC
⢠>0.9
⢠<2 mA at 264 VAC, 60 Hz
⢠LCL150: T3.15 A/250 V,
LCL300: T6.3A/250 V,
LCL500: T10A/250 V,
internal fuse fitted in line
Output
Output Voltage
⢠See tables
Output Voltage Trim ⢠See tables
Initial Set Accuracy ⢠±100 mV at 50% load
Minimum Load
⢠None required
Start Up Delay
⢠2 s max for LCL150, 1.5 s max for LCL300,
0.8 s max for LCL500
Start Up Rise Time
⢠50 ms max for LCL150,
35 ms max for LCL300 & LCL500
Hold Up Time
⢠10 ms min at 115 VAC and full load
Line Regulation
⢠±0.5% max for LCL150,
±0.3% for LCL300 & LCL500
Load Regulation
⢠±1% max
Transient Response
⢠4% max deviation recovery to within 1%
in 500 µs for a 50% load change
Ripple & Noise
⢠See tables
Overvoltage Protection ⢠110-140%, recycle input to reset
Overtemperature
Protection
⢠Output turns off when OTP triggered,
measured internally, auto recovery
Overload Protection
⢠110-150% of rated output power. Delayed
by 1 s min to allow for peak loads.
Short Circuit Protection ⢠Trip and restart (hiccup mode),
auto recovery
Remote Sense
⢠Fitted to LCL500 only, compensates for
0.25 V max each line
Remote On/Off
⢠Fitted on LCL300 & 500 only,
On = logic low or open circuit,
Off = logic high
General
Efficiency
Isolation
Switching Frequency
Power Density
MTBF
⢠88% typical at full load & 230 VAC
⢠3000 VAC Input to Output
1500 VAC Input to Ground
500 VAC Output to Ground
⢠90-110 kHz main converter & 45-190 kHz
PFC for LCL150, 80-190 kHz main converter
& 62-65 kHz PFC for LCL300 & 500
⢠2.7 W/in3 LCL150, 4.4 W/in3 LCL300,
4.9 W/in3 LCL500
⢠LCL150: >489 kHrs,
LCL300: >235 kHrs,
LCL500: >211 kHrs to MIL-HBK-217F at
25 °C, GB
Environmental
Operating Temperature ⢠-10 °C to +70 °C, derate from 100% load
at 50 °C to 50% load at 70 °C
Cooling
⢠LCL150 convection cooled, LCL300 &
LCL500 have internal fans
Operating Humidity ⢠5% to 90% non condensing
Storage Temperature ⢠-40 °C to +85 °C
Operating Altitude
⢠3000 m
Vibration
⢠10-500 Hz, 2 g, 10 mins per cycle on
3 axes
EMC & Safety
Emissions
Harmonic Currents
Voltage Flicker
ESD Immunity
Radiated Immunity
EFT/Burst
Surge
Conducted Immunity
Magnetic Field
Dips & Interruptions
Safety Approvals
⢠EN55022 level B conducted,
level A radiated
⢠EN61000-3-2 class A
LCL150: EN61000-3-2 class C for loads â¥40%
LCL300 & LCL500: EN61000-3-2 class C
for loads â¥20%
⢠EN61000-3-3
⢠EN61000-4-2, ±4 kV contact,
±8 kV air discharge, Performance Criteria A
⢠EN61000-4-3, level 2 Perf Criteria A
⢠EN61000-4-4, level 2 Perf Criteria A
⢠EN61000-4-5,
installation class 3, Perf Criteria A
⢠EN61000-4-6, level 2 Perf Criteria A
⢠EN61000-4-8, 1 A/m Perf Criteria A
⢠EN61000-4-11, 30% 10 ms, 60% 100 ms,
100% 5000 ms, Perf Criteria A, B, B
⢠EN60950-1, UL60950-1, CSA60950
No 22.2
|
▷ |