JTL4024S3V3 Datasheet, PDF (1/2 Pages) XP Power Limited – 40 Watts JTL Series | |||
|
40 Watts
JTL Series
xppower.com
⢠4:1 Input Range
⢠High Power Density
⢠Single and Dual Outputs
⢠High Efficiency Up to 92%
⢠Remote On/Off
⢠1600 VDC Isolation
⢠3 Year Warranty
Specification
Input
Input Voltage Range
Input Current
Input Reflected
Ripple Current
Input Reverse
Voltage Protection
Undervoltage Lockout
Input Filter
Input Surge
⢠24 V (9-36 VDC), 48 V (18-75 VDC)
⢠See table
⢠20 mA pk-pk through 12 µH inductor
⢠None
⢠24 V models: ON 8.6 V, OFF 7.9 V typical
48 V models: ON 17.8 V, OFF 16 V typical
⢠Pi network
⢠24 V models 50 VDC for 100 ms
48 V models 100 VDC for 100 ms
Output
Output Voltage
⢠See table
Output Voltage Trim ⢠±10%
Minimum Load
⢠No minimum load required
Line Regulation
⢠±0.5% max
Load Regulation
⢠Single output models: ±0.5% max
Dual output models: ±1% max
balanced outputs
Cross Regulation
⢠±5% for dual outputs (see note 2)
Setpoint Accuracy
⢠±1%
Start Up Time
⢠25 ms typical
Ripple & Noise
⢠50 mV pk-pk max for 3.3 V & 5 V models,
75 mV pk-pk max for other single output
models, 150 mV pk-pk max for dual output
models, 20 MHz bandwidth, (see note 3)
Transient Response
⢠3% max deviation, recovery to within
1% in <250 µs for a 25% load change
Temperature
Coefficient
⢠0.02%/°C
Overvoltage Protection ⢠3.3 V models: 3.9 V typical
5 V models: 6.2 V typical
12 V models: 15 V typical
15 V models: 18 V typical
±12 V models: ±15 V typical
±15 V models: ±18 V typical
Overload Protection ⢠>130% of full load
Short Circuit Protection ⢠Trip & restart (Hiccup mode), auto recovery
Remote On/Off
⢠On = Logic High (>3.0) or Open
Off = Logic Low (<1.2 V) or short pin 2 to 3
Max Capacitive Load ⢠See table
General
Efficiency
Isolation
Isolation Capacitance
Switching Frequency
Power Density
MTBF
⢠See table
⢠1600 VDC Input to Output
1600 VDC Input to Case
1600 VDC Output to Case
⢠2500 pF max
⢠270 kHz, typical
⢠25 W/in3
⢠150 kHrs min to MIL-HDBK-217F
at 25 °C, GB
Environmental
Operating Temperature ⢠-40 °C to +85 °C, see derating curve
Case Temperature
⢠+105 °C max
Cooling
⢠Convection-cooled
Operating Humidity ⢠5-95% RH, non-condensing
Storage Temperature ⢠-40 °C to +125 °C
EMC & Safety
Emissions
ESD Immunity
EFT/Burst
Surge
Conducted Immunity
Magnetic Fields
⢠EN55022, class A conducted and
radiated with external components
⢠EN61000-4-2, level 3, Perf Criteria A
⢠EN61000-4-4, level 3, Perf Criteria A
(see note 4)
⢠EN61000-4-5, installation class 2,
Perf Criteria A (see note 4)
⢠EN61000-4-6, 3 Vrms, Perf Criteria A
⢠EN61000-4-8, 1 A/m, Perf Criteria A
|
▷ |