English
Language : 

JTC0424S3V3 Datasheet, PDF (1/2 Pages) XP Power Limited – DC-DC Power Supplies
4-6 Watts
JTC04/06 Series
xppower.com
• 4:1 Input Range
• DIP-24 Metal Package
• Operating Temperature -40 ºC to +100 ºC
• Single & Dual Outputs
• Continuous Short Circuit Protection
• 1500 VDC Isolation
• 3000 VDC Isolation Optional
Specification
Input
Input Voltage Range
Input Current
Input Filter
Input Reflected Ripple
Input Surge
• 24 V (9-36 VDC)
48 V (18-72 VDC)
• See table
• Pi network
• 35 mA pk-pk through 12 µH inductor,
5 Hz to 20 MHz
• 24 V models 40 VDC for 100 ms
48 V models 80 VDC for 100 ms
Output
Output Voltage
• See table
Output Voltage Balance • ±1% max, dual output models
Minimum Load
• No minimum load required
Intial Set Accuracy
• ±1% max
Start Up Delay
• <800 ms
Start Up Rise Time
• <10 ms
Line Regulation
• ±0.5% max
Load Regulation
• ±0.5% max
Cross Regulation
• ±5% on dual output models
Transient Response
• <1.5% max deviation, recovery to within
1% in 200 µs for a 50% load change
Ripple & Noise
• 60 mV pk-pk for 3.3 V to 15 V models,
100 mV pk-pk for 18 V models,
150 mV pk-pk for 24 V models,
20 MHz BW
Short Circuit Protection • Trip & restart (hiccup) with auto recovery
Maximum Capacitive • See tables
Load
Temperature
Coefficient
• ±0.02/°C max
General
Efficiency
Isolation
Isolation Capacitance
Switching Frequency
MTBF
• See tables
• 1500 VDC Input to Output, for optional
high isolation version 3000 VDC input to
output add suffix ‘-H’ to model number
1000 VDC Input to Case
1000 VDC Output to Case
• 500 pF max
• 266 kHz typical
• >1 MHrs to MIL-STD-217F
Environmental
Operating Temperature • -40 ºC to +100 ºC, derate from 100% load
at +85 °C to no load at +100 °C
Case Temperature
• +100 ºC max
Storage Temperature • -40 ºC to +125 ºC
Humidity
• Up to 90%, non-condensing
Cooling
• Natural convection
EMC
Emissions
ESD Immunity
Radiated Immunity
• EN55022 Class A conducted with external
components - see application note
• EN61000-4-2,
8 kV air discharge Perf Criteria A,
4 kV contact discharge Perf Criteria A
• EN61000-4-6 Level 2 3 V/m Perf Criteria A