JTC04 Datasheet, PDF (1/2 Pages) XP Power Limited – 4/6 Watts JTC Series
4/6 Watts
JTC Series
xppower.com
• 4:1 Input Range
• DIP 24 Metal Package
• Operating Temperature 40 °C to +100 °C
• Single & Dual Outputs
• Continuous Short Circuit Protection
• 1500 VDC Isolation, 3500 VDC Option
• 3 Year Warranty
Specification
Input
Input Voltage Range
Input Current
Input Filter
Input Reflected Ripple
Input Surge
Undervoltage Lockout
Input Reverse Voltage
Protection
• 24 V (9-36 VDC)
48 V (18-72 VDC)
• See table
• Pi network
• 35 mA pk-pk through 12 µH inductor
• 24 V models 40 VDC for 100 ms
48 V models 80 VDC for 100 ms
• None
• None
Output
Output Voltage
• See table
Output Voltage Balance • ±1% max, dual output models
Minimum Load
• No minimum load required
Initial Set Accuracy • ±1% max
Start Up Delay
• <800 ms
Start Up Rise Time
• <10 ms
Line Regulation
• ±0.5% max
Load Regulation
• ±0.5% max, ±1.5% max for 3.3 V and
±3.3 V models
Cross Regulation
• ±5% on dual output models (see note 4)
Transient Response
• <1.5% max deviation, recovery to within
1% in 200 µs for a 50% load change
Ripple & Noise
• 60 mV pk-pk for 3.3 V to 15 V models,
100 mV pk-pk for 18 V models,
150 mV pk-pk for 24 V models,
20 MHz bandwidth
Short Circuit Protection • Trip & restart (Hiccup mode),
auto recovery
Maximum Capacitive • See tables
Load
Temperature
Coefficient
• ±0.02/°C max
General
Efficiency
Isolation Voltage
Isolation Resistance
Switching Frequency
Power Density
MTBF
• See tables
• 1500 VDC Input to Output, for optional
high isolation version 3500 VDC input to
output add suffix ‘-H’ to model number
1000 VDC Input to Case
1000 VDC Output to Case
• 109Ω
• 266 kHz typical
• JTC04: 10 W/in3, JTC06: 15 W/in3
• >1.0 MHrs to MIL-HDBK-217F
at 25 °C, GB
Environmental
Operating Temperature • -40 °C to +100 °C, derate from 100% load
at +85 °C to no load at +100 °C
Case Temperature
• +100 °C max
Storage Temperature • -40 °C to +125 °C
Humidity
• Up to 95%, non-condensing
Cooling
• Natural convection
EMC
Emissions
ESD Immunity
EFT/Burst
Conducted Immunity
Magnetic Fields
• EN55022 class A conducted with external
components - see application note
• EN61000-4-2,
8 kV air discharge Perf Criteria A,
4 kV contact discharge Perf Criteria A
• EN61000-4-4, level 1, Perf Criteria A
• EN61000-4-6, 3 Vrms, Perf Criteria A
• EN61000-4-8, 1 A/m, Perf Criteria A