JTB0324S3V3 Datasheet, PDF (1/2 Pages) XP Power Limited – DC-DC Power Supplies | |||
|
3 Watts
JTB03 Series
xppower.com
⢠4:1 Input Range
⢠DIP-24 Metal Package
⢠Operating Temperature -25 °C to +100 °C
⢠Input Pi Filter
⢠Fully Regulated Single & Dual Outputs
⢠Optional 1500 VDC Isolation
⢠Continuous Short Circuit Protection
Specification
Input
Input Voltage Range
Input Current
Input Filter
⢠24 V (9-36 VDC)
48 V (18-72 VDC)
⢠See table
⢠Pi network
Output
Output Voltage
⢠See table
Output Voltage Balance ⢠±1% max, dual output models
Intial Set Accuracy
⢠±2% max
Start Up Delay
⢠90 ms max
Start Up Rise Time
⢠35 ms typical
Line Regulation
⢠±0.5% max (high line to low line)
Load Regulation
⢠±0.5% max single output models,
±1.0% max for dual output models
Cross Regulation
⢠2.2% on dual output models
Transient Response
⢠<1.5% max deviation, recovery to within
1% in 200 µs for a 50% load change
Ripple & Noise
⢠100 mV or 1% pk-pk, whichever is
greater, 20 MHz BW
Overcurrent Protection ⢠>170% fold back at normal input voltage
Short Circuit Protection ⢠Continuous with auto recovery
Maximum Capacitive ⢠30,000 µF
Load
Temperature
Coefficient
⢠±0.05/°C max
General
Efficiency
Isolation
Switching Frequency
MTBF
⢠See table
⢠500 VDC Input to Output (1000 Mâ¦/80 pF)
Optional high isolation version,
1500 VDC Input to Output, add suffix â-Hâ
to model number
⢠Variable 100-700 kHz
⢠1,000 kHrs to MIL-HDBK-217F
Environmental
Operating Temperature ⢠-25 °C to +100 °C (see derating curve)
Case Temperature
⢠+100 °C max
Storage Temperature ⢠-40 °C to +100 °C
Shock
⢠30 g, half sine wave 18 ms pulse applied
3 times on each of 6 axes
Vibration
⢠5-500 Hz, 3 g, for 10 mins on each
of 3 axes
EMC
Emissions
ESD Immunity
Radiated Immunity
Conducted Immunity
⢠EN55022, level A conducted & radiated
with external components - see
application note
⢠EN61000-4-2, level 2 Perf Criteria A
⢠EN61000-4-3, 3 V/m Perf Criteria A
⢠EN61000-4-6, 3 V rms Perf Criteria A
|
▷ |