JTB03 Datasheet, PDF (1/2 Pages) XP Power Limited – DIP24 Metal Package | |||
|
3 5 Watts
JTB03/05 Series
xppower.com
⢠4:1 Input Range
⢠DIP 24 Metal Package
⢠Operating Temperature 25 °C to +100 °C
⢠Fully Regulated Single & Dual Outputs
⢠Optional 1500 VDC Isolation
⢠Continuous Short Circuit Protection
⢠3 Year Warranty
Specification
Input
Input Voltage Range
Input Current
Input Filter
Input Surge
⢠24 V (9-36 VDC)
48 V (18-72 VDC)
⢠See table
⢠Pi network
⢠24 V models 50 V for 100 ms
48 V models 100 V for 100 ms
Output
Output Voltage
⢠See table
Output Voltage Balance ⢠±1% max, dual output models
Intial Set Accuracy
⢠±2% max
Start Up Delay
⢠90 ms max
Start Up Rise Time
⢠35 ms typical
Line Regulation
⢠±0.5% max (high line to low line)
Load Regulation
⢠±0.5% max single output models,
±1.0% max for dual output models
Cross Regulation
⢠2.2% on dual output models
Transient Response
⢠<1.5% max deviation, recovery to within
1% in 800 µs for a 50% load change
Ripple & Noise
⢠100 mV or 1% pk-pk, whichever is
greater, 20 MHz bandwidth
Overcurrent Protection ⢠JTB03: >170% fold back at nominal
input voltage
JTB05: >130% constant power
Short Circuit Protection ⢠JTB03: Continuous, hiccup mode,
auto-restart
JTB05: Continuous, current limit,
auto-restart
Maximum Capacitive ⢠10,000 µF
Load
Temperature
Coefficient
⢠±0.05/°C max
General
Efficiency
Isolation
Isolation Capacitance
Switching Frequency
MTBF
⢠See table
⢠JTB03: 500 VDC Input to Output
1500 VDC Input to Output, add suffix â-Hâ
JTB05: 1500 VDC Input to Output
⢠80 pF max
⢠Variable 100-700 kHz
⢠>1.0 MHrs to MIL-HDBK-217F
at 25 ÅC, GB
Environmental
Operating Temperature ⢠-25 °C to +100 °C, derate linearly from
100% load at +70 ÅC to no load at 100 ÅC
Case Temperature
⢠+100 °C max
Storage Temperature ⢠-40 °C to +100 °C
Shock
⢠30 g, half sine wave 18 ms pulse applied
3 times on each of 6 axes
Vibration
⢠5-500 Hz, 3 g, for 10 mins on each
of 3 axes
EMC
Emissions
ESD Immunity
Radiated Immunity
Conducted Immunity
⢠EN55022, level A conducted &
radiated with external components,
see application note
⢠EN61000-4-2, level 2 Perf Criteria A
⢠EN61000-4-3, 3 V/m Perf Criteria A
⢠EN61000-4-6, 3 V rms Perf Criteria A
|
▷ |