JTA1024S3V3 Datasheet, PDF (1/4 Pages) XP Power Limited – DC-DC Power Supplies | |||
|
10-20 Watts
JTA Series
xppower.com
⢠4:1 Input Range
⢠-40 ËC to +100 ËC Operating Temperature
⢠Single & Dual Outputs
⢠Overvoltage & Overcurrent Protection
⢠UL Safety Approvals
⢠Remote On/Off
⢠1500 VDC Isolation
Specification
Input
Input Voltage Range
Input Current
⢠9-36 VDC
18-75 VDC
⢠JTA10: 1.65 A max at 9 VDC input
JTA15: 2.20 A max at 9 VDC input
JTA20: 2.90 A max at 9 VDC input
Output
Output Voltage
⢠See table
Output Voltage Trim ⢠±10% (15 & 20 W models only)
Voltage Balance
⢠±1% max dual models, 100% load
Minimum Load
⢠No minimum load required for single
output models, 10% required for dual
output models
Line Regulation
⢠±1% max
Load Regulation
⢠Single output models: ±1% max
Dual output models: ±2% max
for a 10-100% load change
Setpoint Accuracy
⢠±2%
Ripple & Noise
⢠Single output models: 50 mV pk-pk
Dual output models: 75 mV pk-pk typical
at 20 MHz BW
Transient Response
⢠4% max deviation, recovery to within
1% in <500 µs for a 25% load change
Temperature
Coefficient
⢠0.02%/ºC
Overvoltage Protection ⢠See table
Overcurrent Protection ⢠Continuous with auto recovery
Remote On/Off
⢠On = Logic High or Open
Off = Logic Low or <1.8 V
(15 & 20 W models only)
General
Efficiency
Isolation
MTBF
⢠See table
⢠1500 VDC Input to Output
⢠1,000 kHrs min per MIL-HDBK-217F
Environmental
Operating Temperature ⢠-40 ºC to +100 ºC, see derating curve
Case Temperature
⢠+100 °C max
Cooling
⢠Natural convection
Operating Humidity ⢠5-95% RH, non-condensing
Storage Temperature ⢠-55 ºC to +105 ºC
EMC & Safety
Emissions
ESD Immunity
Radiated Immunity
Conducted Immunity
Safety Approvals
⢠EN55022,
level A conducted (below -25 ºC)
level B conducted (-25 ºC to +100 ºC)
See note 1.
EN55022, level A radiated
⢠EN61000-4-2, level 2
Perf Criteria A
⢠EN61000-4-3 3 V/rms,
Perf Criteria A
⢠EN61000-4-6 3 V/m,
Perf Criteria A
⢠UL60950-1
|
▷ |