JPS350PS05C Datasheet, PDF (1/4 Pages) XP Power Limited – AC-DC Power Supplies | |||
|
350 Watts
JPS350 Series
xppower.com
⢠300 W with Convection Cooling
⢠High Efficiency - up to 90%
⢠Remote On/Off & Remote Sense
⢠Meets 1U, Low Profile Requirements
⢠Zero Voltage Switching Technology
⢠AC OK & DC OK Signals
⢠Current Sharing
Specification
Input
Input Voltage
⢠85-264 VAC (170-370 VDC)
Input Frequency
⢠47-63 Hz
Input Current
⢠4 A/2 A max at 115 VAC/230 VAC
Inrush Current
⢠30 A at 115 VAC, 60 A at 230 VAC
Power Factor
⢠0.99 typical
Earth Leakage Current ⢠2.0 mA max 264 VAC/60 Hz
Input Protection
⢠Internal 6.3 A, 250 V fuse
Output
Output Voltage
⢠See table
Output Voltage Trim ⢠±10% single output models only
Initial Set Accuracy
⢠At 60% rated load ±1% output V1 & V2,
±5% on output V3 & V4
Minimum Load
⢠No minimum load required on single
output models. For multi-output models
see note 5
Start Up Delay
⢠2 s typical
Start Up Rise Time
⢠100 ms typical
Hold Up Time
⢠20 ms min at low line
Line Regulation
⢠±0.5% at rated load across input
voltage range
Load Regulation
⢠±1% for single output models &
V1 & V2 of multi-output models
±5% for V3 & V4
Tolerance
⢠±1%
Transient Response
⢠4% max deviation, recovery to within
1% in 500 µs for a 25% load change
Ripple & Noise
⢠±1% max pk-pk, 20 MHz BW
Overvoltage Protection ⢠115-140%, recycle input to reset
Overtemperature
Protection
⢠Shuts down at +110 °C, auto recovery
Overload Protection ⢠120-150%, auto recovery
Short Circuit Protection ⢠Trip and restart (Hiccup mode)
Temperature
Coefficient
⢠±0.05%/°C
Remote Sense
⢠Compensates for up to 0.5 V drop
Remote On/Off
Current Share
Fan Output
⢠On = Logic Low or Open
Off = Logic High
⢠Single wire current sharing
(4 supplies can be paralleled)
⢠See mechanical detail notes
General
Efficiency
Isolation
Switching Frequency
Power Density
Signals
MTBF
⢠Up to 90%
⢠3000 VAC Input to Output
1500 VAC Input to Ground
500 VAC Output to Ground
⢠120 kHz typical for PFC & PWM
⢠4.96 W/In3
⢠AC OK, DC OK and Remote On/Off
(see control and supervisory signals)
⢠100 kHrs per MIL-HDBK-217F
Environmental
Operating Temperature ⢠0 °C to +70 °C, (see derating curve)
Full power to +50 °C
Cooling
⢠350 W with 18 CFM airflow
300 W convection cooling
Operating Humidity ⢠5-95% RH, non-condensing
Storage Temperature ⢠-20 °C to +85 °C
Operating Altitude
⢠3000 m
Vibration
⢠2 g, 10-55 Hz, 3 mins/cycle for
30 mins each axis
EMC & Safety
Emissions
Harmonic Currents
Voltage Flicker
ESD Immunity
Radiated Immunity
EFT/Burst
Surge
Safety Approvals
⢠EN55022, level B conducted
FCC 20780, level B conducted
⢠EN61000-3-2
⢠EN61000-3-3
⢠EN61000-4-2, level 3 Perf Criteria A
⢠EN61000-4-3, 10 V/m Perf Criteria A
⢠EN61000-4-4, level 3 Perf Criteria A
⢠EN61000-4-5, level 3 Perf Criteria A
⢠EN60950-1:2001, UL60950-1, CSA C22.2
No. 60950-1, CE Mark LVD
|
▷ |