JPS Datasheet, PDF (1/2 Pages) XP Power Limited – 100 W Convection-cooled | |||
|
130 Watts
JPS Series
xppower.com
⢠High Efficiency up to 90%
⢠Medical Approval (JPS130 M Versions)
⢠3â x 5â Footprint
⢠100 W Convection cooled
⢠130 W Forced cooled
⢠Single & Multi Outputs
⢠3 Year Warranty
Specification
Input
General
Input Voltage
⢠90-264 VAC (130-370 VDC)
Efficiency
⢠Up to 90% nominal line, full load
Input Frequency
⢠47-63 Hz
Input Current
⢠2.0/1.0 A max at 115/230 VAC (JPS130)
2.6/1.3 A max at 115/230 VAC (JPS130-M)
Inrush Current
⢠30 A at 115 VAC, 60 A at 230 VAC,
cold start at 25 °C
Power Factor
⢠0.9 typical
Earth Leakage Current ⢠1.5 mA max at 264 VAC/60 Hz (JPS130)
260 µA max at 275 VAC/63 Hz (JPS130-M)
Isolation
Switching Frequency
Power Density
MTBF
⢠3000 VAC Input to Output (JPS130),
4000 VAC Input to Output (JPS130-M
2 x MOPP), 1500 VAC Input to Ground
(JPS130-M 1 x MOPP),
500 VAC Output to Ground
⢠120 kHz, ±10% for both active PFC & PWM
⢠6.7 W/In3
⢠200 kHrs to MIL-HDBK-217F at 50 °C, GB
Input Protection
⢠JPS130 internal T3.15 A/250 VAC fused line,
JPS130-M fused line & neutral
Environmental
Operating Temperature ⢠0 °C to +70 °C, (see derating curves)
Output
Output Voltage
Output Voltage Trim
Initial Set Accuracy
⢠See table
⢠±10% on single output models,
±5% on multi output models,
auxiliary outputs will track by the same
percentage
⢠At 60% rated load ±1% single outputs,
±3% on V1 for multi outputs
Cooling
Operating Humidity
Storage Temperature
Operating Altitude
⢠JPS130PS03 83 W convection-cooling,
100 W, with 18 CFM airflow.
All others, 100 W with convection
cooling,130 W with 18 CFM airflow
⢠5-95% RH, non-condensing
⢠-40 °C to +85 °C (JPS130)
-20 °C to +85 °C (JPS130-M)
⢠3000 m
Minimum Load
Start Up Rise Time
Hold Up Time
Drift
Line Regulation
Load Regulation
Transient Response
⢠Single output: no minimum load required
Multi-outputs: (see note 1)
⢠<20 ms
EMC & Safety
Emissions
⢠16 ms typical at 115 VAC & rated load (JPS130)
20 ms typical at 115 VAC & rated load (JPS130-M)
⢠<±0.2% after 20 mins warm up
⢠±0.5% Vmin to Vmax
Harmonic Currents
Voltage Flicker
⢠±1%, ±5% for auxiliary outputs,
ESD Immunity
20%-100% of rated load
⢠4% max deviation, recovery to within
Radiated Immunity
1% in 500 µs for a 25% load change
EFT/Burst
⢠EN55022, Class B conducted
FCC 20780, level B conducted
EN60601-1-2, (JPS130-M)
⢠EN61000-3-2 Class A
⢠EN61000-3-3
⢠EN61000-4-2, level 3 contact, level 3 air,
Perf Criteria A
⢠EN61000-4-3, 10 V/m Perf Criteria A
⢠EN61000-4-4, level 3 Perf Criteria A
Ripple & Noise
⢠±1% max pk-pk (see note 4)
Overvoltage Protection ⢠110-140% Vnom on V1 only,
recycle input to reset
Overload Protection ⢠110-150%, auto recovery
Short Circuit Protection ⢠Trip & restart (hiccup mode), auto recovery
Surge
Conducted Immunity
Dips & Interruptions
⢠EN61000-4-5, Installation Class 3
Perf Criteria A
⢠EN61000-4-6, level 2, Perf Criteria A
⢠EN61000-4-11, 30% 10 ms, 60% 100 ms,
95% 5000 ms Perf Criteria A, B, B
Temperature
Coefficient
Remote Sense
Fan Output
⢠0.05%/°C
Safety Approvals
⢠Single output models only, compensates for
up to 0.5 V drop
⢠12 V, 450 mA multi-output models only
⢠JPS130: EN60950-1, UL60950-1,
CSA C22.2 No. 60950-1,
CE Mark LVD.
JPS130-M: UL60601-1, EN60601-1,
CSA C22.2 No. 601.1
CE Mark LVD.
|
▷ |