JPP130PD02 Datasheet, PDF (1/2 Pages) XP Power Limited – DC-DC Power Supplies | |||
|
130 Watts
JPP130 Series
xppower.com
⢠High Power Density
⢠Small Footprint
⢠Up to Five DC Outputs
⢠Wide Adjustment on Two Outputs
⢠Short Circuit Protection with Auto Recovery
⢠Power Fail Signal
⢠Active Power Factor Correction
Specification
Input
Input Voltage
Input Frequency
Input Current
Inrush Current
Power Factor
⢠90-264 VAC
⢠47-63 Hz
⢠2.10 A at 115 VAC, 1.10 A at 230 VAC
⢠35 A at 115 VAC, 70 A at 230 VAC
⢠0.98 typical
Output
Output Voltage
⢠See table
Output Voltage Trim ⢠User adjustable (see note 3)
Initial Set Accuracy ⢠2% except V2: 3%
Minimum Load
⢠See note 4
Start Up Delay
⢠2 s max
Start Up Rise Time
⢠12 ms max
Hold Up Time
⢠15 ms min
Line Regulation
⢠±0.5% max
Transient Response
⢠4% max. deviation, 500 µs recovery time
for a 25% load change
Ripple & Noise
⢠65 mV for V1, 1% pk-pk on all other
outputs, 20 MHz BW
Overvoltage Protection ⢠V1, V2 & V5 only: 112-132% of nominal
Temperature
Coefficient
⢠0.04% / ºC
Remote Sense
⢠On 3.3 V output only: Compensates for
up to 0.5 V drop
General
Efficiency
Isolation
Power Density
Signals
MTBF
⢠75% typical
⢠3000 VAC Input to Output
1500 VAC Input to Ground
500 VAC Output to Ground
⢠7.2 W/In3
⢠PFD = TTL Level (see note 5)
⢠200 kHrs per MIL-STD-217F
Environmental
Operating Temperature ⢠-10 ºC to +60 ºC, derate from 100% load
at +40 ºC to 50% load at +60 ºC
Cooling
⢠10 CFM
Operating Humidity ⢠5-95% RH, non-condensing
Storage Temperature ⢠-40 ºC to + 85 ºC
Shock
⢠20 G on 3 axis, 3 times each
Vibration
⢠10-55 Hz, 0.15 at 1 octave/min for
30 mins on each 3 axis
EMC & Safety
Emissions
Harmonic Currents
Voltage Flicker
EFT/Burst
Surge
Conducted Immunity
Magnetic Field
Dips & Interruptions
Safety Approvals
⢠EN55022 FCC part 15 and VCCI level B
conducted and level A radiated
⢠EN61000-3-2
⢠EN61000-3-3
⢠EN61000-4-4, level 2 Perf Criteria A
⢠EN61000-4-5, level 3 Perf Criteria A
⢠EN61000-4-6, 3 V Perf Criteria A
⢠EN61000-4-8, 1 A/m Perf Criteria A
⢠EN61000-4-11, 30% 10 ms,
60% 100 ms, 100% 5000 ms,
Perf Criteria A, B, B
⢠UL60950, CSA C22.2 No. 60950,
EN60950, CE Mark LVD
|
▷ |