English
Language : 

JPP130PD02 Datasheet, PDF (1/2 Pages) XP Power Limited – DC-DC Power Supplies
130 Watts
JPP130 Series
xppower.com
• High Power Density
• Small Footprint
• Up to Five DC Outputs
• Wide Adjustment on Two Outputs
• Short Circuit Protection with Auto Recovery
• Power Fail Signal
• Active Power Factor Correction
Specification
Input
Input Voltage
Input Frequency
Input Current
Inrush Current
Power Factor
• 90-264 VAC
• 47-63 Hz
• 2.10 A at 115 VAC, 1.10 A at 230 VAC
• 35 A at 115 VAC, 70 A at 230 VAC
• 0.98 typical
Output
Output Voltage
• See table
Output Voltage Trim • User adjustable (see note 3)
Initial Set Accuracy • 2% except V2: 3%
Minimum Load
• See note 4
Start Up Delay
• 2 s max
Start Up Rise Time
• 12 ms max
Hold Up Time
• 15 ms min
Line Regulation
• ±0.5% max
Transient Response
• 4% max. deviation, 500 µs recovery time
for a 25% load change
Ripple & Noise
• 65 mV for V1, 1% pk-pk on all other
outputs, 20 MHz BW
Overvoltage Protection • V1, V2 & V5 only: 112-132% of nominal
Temperature
Coefficient
• 0.04% / ºC
Remote Sense
• On 3.3 V output only: Compensates for
up to 0.5 V drop
General
Efficiency
Isolation
Power Density
Signals
MTBF
• 75% typical
• 3000 VAC Input to Output
1500 VAC Input to Ground
500 VAC Output to Ground
• 7.2 W/In3
• PFD = TTL Level (see note 5)
• 200 kHrs per MIL-STD-217F
Environmental
Operating Temperature • -10 ºC to +60 ºC, derate from 100% load
at +40 ºC to 50% load at +60 ºC
Cooling
• 10 CFM
Operating Humidity • 5-95% RH, non-condensing
Storage Temperature • -40 ºC to + 85 ºC
Shock
• 20 G on 3 axis, 3 times each
Vibration
• 10-55 Hz, 0.15 at 1 octave/min for
30 mins on each 3 axis
EMC & Safety
Emissions
Harmonic Currents
Voltage Flicker
EFT/Burst
Surge
Conducted Immunity
Magnetic Field
Dips & Interruptions
Safety Approvals
• EN55022 FCC part 15 and VCCI level B
conducted and level A radiated
• EN61000-3-2
• EN61000-3-3
• EN61000-4-4, level 2 Perf Criteria A
• EN61000-4-5, level 3 Perf Criteria A
• EN61000-4-6, 3 V Perf Criteria A
• EN61000-4-8, 1 A/m Perf Criteria A
• EN61000-4-11, 30% 10 ms,
60% 100 ms, 100% 5000 ms,
Perf Criteria A, B, B
• UL60950, CSA C22.2 No. 60950,
EN60950, CE Mark LVD