JPM80PS03 Datasheet, PDF (1/4 Pages) XP Power Limited – DC-DC Power Supplies | |||
|
80-160 Watts
JPM Series
xppower.com
⢠Low Cost
⢠High Reliability
⢠Power Factor Corrected
⢠Suitable for Battery-charging Applications
⢠Low Ripple & Noise
⢠125% Rating at 230 VAC
⢠Optional Remote On/Off
Specification
Input
Input Voltage
⢠85-264 VAC (120-370 VDC)
Input Frequency
⢠47-63 Hz
Input Current
⢠JPM80: 0.7 A max at 230 VAC
JPM120: 1.1 A max at 230 VAC
JPM160: 1.4 A max at 230 VAC
Inrush Current
⢠40 A at 230 VAC cold start
Power Factor
⢠>0.9
Earth Leakage Current ⢠<2 mA at 230 VAC
Output
Output Voltage
⢠See tables
Output Voltage Trim ⢠+10%, -5%
Initial Set Accuracy ⢠±2%
Start Up Delay
⢠600 ms max
Start Up Rise Time
⢠30 ms max
Hold Up Time
⢠25 ms min
Line Regulation
⢠±0.5%
Load Regulation
⢠See tables
Ripple & Noise
⢠See tables
Overvoltage Protection ⢠110-135% Vnom, recycle input to reset
Overtemperature
Protection
⢠Shuts down at +95 °C ±5 °C (measured
internally) with auto recovery, only on
JPM120 & JPM160
Overload Protection ⢠105-150% constant current, auto recovery
Temperature
Coefficient
⢠±0.05%/°C
Remote On/Off
⢠4-10 VDC On, <0.8 VDC Off, optional.
Add suffix âRâ to model number
General
Efficiency
Isolation
MTBF
⢠See tables
⢠3000 VAC Input to Output
1500 VAC Input to Ground
500 VAC Output to Ground
⢠>183 kHrs per MIL-HDBK-217F (+25 °C)
Environmental
Operating Temperature ⢠-10 °C to +60 °C, see derating curves
Cooling
⢠JPM80 & JPM120 convection-cooled,
JPM160 includes internal fan
Operating Humidity ⢠20-90% RH, non-condensing
Storage Temperature ⢠-20 °C to +85 °C
Vibration
⢠2 g, 10-500 Hz, 10 min/cycle for 60
minutes each axis
EMC & Safety
Emissions
Harmonic Currents
Voltage Flicker
ESD Immunity
Radiated Immunity
EFT/Burst
Surge
Conducted Immunity
Magnetic Field
Dips & Interruptions
Safety Approvals
⢠EN55022 (CISPR22), level B conducted
EN55022 (CISPR22), level B radiated
⢠EN61000-3-2
⢠EN61000-3-3
⢠EN61000-4-2, level 3 Perf Criteria A
⢠EN61000-4-3, 3 V/m Perf Criteria A
⢠EN61000-4-4, level 2 Perf Criteria A
⢠EN61000-4-5, level 3 Perf Criteria A
⢠EN61000-4-6, level 2 Perf Criteria A
⢠EN61000-4-8, 3 A/m Perf Criteria A
⢠EN61000-4-11, 30% 10 ms,
60% 100 ms, >95% 5000 ms,
Perf Criteria A, B, B
⢠EN60950-1-1:2001, UL60950-1,
CSA22.2 No. 60950-1, CE Mark LVD
|
▷ |