JCL2524S1V8 Datasheet, PDF (1/2 Pages) XP Power Limited – DC-DC Power Supplies | |||
|
25 Watts
JCL Series
xppower.com
⢠2:1 Input Range
⢠High Efficiency up to 90%
⢠-40 °C to +100 °C Operating Temperature
⢠Fixed 300 kHz Switching Frequency
⢠Regulated Single Outputs
⢠Continuous Short Circuit Protection
⢠Six-sided Metal Case or Open Frame
Specification
Input
Input Voltage Range
Input Current
Input Filter
Undervoltage Lockout
⢠24 VDC (18-36 VDC)
48 VDC (36-75 VDC)
⢠See table
⢠Pi network
⢠Turn on >71% nominal input,
Turn off <67% nominal input
Output
Output Voltage
⢠See table
Output Voltage Adj
⢠±10%
Minimum Load
⢠No minimum load required
Line Regulation
⢠±0.5% max
Load Regulation
⢠±0.5% max from 10% to full load
Setpoint Accuracy
⢠±1.0% max
Ripple & Noise
⢠1.8 V, 2.5 V, 3.3 V & 5.0 V models
75 mV pk-pk max (20 MHz bandwidth)
12.0 V & 15.0 V models
100 mV pk-pk max (20 MHz bandwidth)
Transient Response
⢠5% max deviation, recovery to within
1% in 300 µs for a 25% load change
Temperature
Coefficient
⢠0.02%/°C
Overvoltage Protection ⢠1.8 V & 2.5 V models 3.3 V typical,
3.3 V models 3.9 V typical,
5.0 V models 6.2 V typical,
12.0 V models 15.0 V typical,
15.0 V models 18.0 V typical
Overcurrent Protection ⢠110-150%
Short Circuit Protection ⢠Trip & restart (hiccup mode)
Remote On/Off
⢠ON >3.5 VDC or open circuit
OFF <1.8 VDC
Optional negative logic, add suffix â-Nâ
to model number
Thermal Protection
⢠Shuts down when case measures
+110 °C typical
General
Efficiency
Isolation Voltage
Switching Frequency
MTBF
⢠See table
⢠1500 VDC Input to Output
1500 VDC Input to Case
-V Output is connected to case
⢠300 kHz typical
⢠>750 kHrs to MIL-STD-217F
Environmental
Operating Temperature ⢠-40 °C to +100 °C (see derating curve)
Case Temperature
⢠+100 °C max
Storage Temperature ⢠-55 °C to +125 °C
Cooling
⢠Convection-cooled
Operating Humidity ⢠Up to 90%, non-condensing
Shock
⢠30 g, half sine wave 18 ms pulse applied
3 times on each of 6 axes
Vibration
⢠5-500 Hz, 3 g, for 10 mins on each
of 3 axes
EMC
Emissions
ESD Immunity
Radiated Immunity
Conducted Immunity
⢠EN55022, Level A conducted & radiated
with external components - contact
technical sales
⢠EN61000-4-2, Level 2 Perf Criteria A
⢠EN61000-4-3, 3 V/m Perf Criteria A
⢠EN61000-4-6, 3 V rms Perf Criteria A
|
▷ |