English
Language : 

JCL2524S1V8 Datasheet, PDF (1/2 Pages) XP Power Limited – DC-DC Power Supplies
25 Watts
JCL Series
xppower.com
• 2:1 Input Range
• High Efficiency up to 90%
• -40 °C to +100 °C Operating Temperature
• Fixed 300 kHz Switching Frequency
• Regulated Single Outputs
• Continuous Short Circuit Protection
• Six-sided Metal Case or Open Frame
Specification
Input
Input Voltage Range
Input Current
Input Filter
Undervoltage Lockout
• 24 VDC (18-36 VDC)
48 VDC (36-75 VDC)
• See table
• Pi network
• Turn on >71% nominal input,
Turn off <67% nominal input
Output
Output Voltage
• See table
Output Voltage Adj
• ±10%
Minimum Load
• No minimum load required
Line Regulation
• ±0.5% max
Load Regulation
• ±0.5% max from 10% to full load
Setpoint Accuracy
• ±1.0% max
Ripple & Noise
• 1.8 V, 2.5 V, 3.3 V & 5.0 V models
75 mV pk-pk max (20 MHz bandwidth)
12.0 V & 15.0 V models
100 mV pk-pk max (20 MHz bandwidth)
Transient Response
• 5% max deviation, recovery to within
1% in 300 µs for a 25% load change
Temperature
Coefficient
• 0.02%/°C
Overvoltage Protection • 1.8 V & 2.5 V models 3.3 V typical,
3.3 V models 3.9 V typical,
5.0 V models 6.2 V typical,
12.0 V models 15.0 V typical,
15.0 V models 18.0 V typical
Overcurrent Protection • 110-150%
Short Circuit Protection • Trip & restart (hiccup mode)
Remote On/Off
• ON >3.5 VDC or open circuit
OFF <1.8 VDC
Optional negative logic, add suffix ‘-N’
to model number
Thermal Protection
• Shuts down when case measures
+110 °C typical
General
Efficiency
Isolation Voltage
Switching Frequency
MTBF
• See table
• 1500 VDC Input to Output
1500 VDC Input to Case
-V Output is connected to case
• 300 kHz typical
• >750 kHrs to MIL-STD-217F
Environmental
Operating Temperature • -40 °C to +100 °C (see derating curve)
Case Temperature
• +100 °C max
Storage Temperature • -55 °C to +125 °C
Cooling
• Convection-cooled
Operating Humidity • Up to 90%, non-condensing
Shock
• 30 g, half sine wave 18 ms pulse applied
3 times on each of 6 axes
Vibration
• 5-500 Hz, 3 g, for 10 mins on each
of 3 axes
EMC
Emissions
ESD Immunity
Radiated Immunity
Conducted Immunity
• EN55022, Level A conducted & radiated
with external components - contact
technical sales
• EN61000-4-2, Level 2 Perf Criteria A
• EN61000-4-3, 3 V/m Perf Criteria A
• EN61000-4-6, 3 V rms Perf Criteria A