JCJ1012S2V5 Datasheet, PDF (1/2 Pages) XP Power Limited – DC-DC Power Supplies | |||
|
10 Watts
JCJ10 Series
xppower.com
⢠2:1 Input Range
⢠DIP-24 Metal Package
⢠Operating Temperature -40 ºC to +100 ºC
⢠Single & Dual Outputs
⢠Continuous Short Circuit Protection
⢠1500 VDC Isolation
⢠High Efficiency - Up to 90%
Specification
Input
Input Voltage Range
Input Current
Input Filter
Input Reflected Ripple
Input Surge
⢠12 V (9-18 VDC)
24 V (18-36 VDC
48 V (36-75 VDC)
⢠See table
⢠Pi network
⢠20 mA pk-pk through 12 µH inductor,
5 Hz to 20 MHz
⢠12 V models 25 VDC for 100 ms
24 V models 50 VDC for 100 ms
48 V models 100 VDC for 100 ms
Output
Output Voltage
⢠See table
Output Voltage Balance ⢠±1% max, dual output models
Minimum Load
⢠No minimum load required
Initial Set Accuracy ⢠±1% max
Start Up Delay
⢠<20 ms
Start Up Rise Time
⢠<10 ms
Line Regulation
⢠±0.5% max
Load Regulation
⢠±0.7% for 2.5-3.3 V models,
±0.5% for all others, see note 2
Cross Regulation
⢠±5% on dual output models, see note 3
Transient Response
⢠<3% max deviation, recovery to within 1%
in 250 µs for a 25% load change
Ripple & Noise
⢠85 mV pk-pk, 20 MHz BW, with 1 µF
ceramic capacitor, see note 4
Overload Protection ⢠>150%
Overvoltage Protection ⢠2.5-3.3 V models: 3.9 V typical
5 V models: 6.2 V typical
12 V models: 15 V typical
15 V models: 18 V typical
±12 V models: ±15 V typical
±15 V models: ±18 V typical
Short Circuit Protection ⢠Trip & restart (hiccup) with auto recovery
Maximum Capacitive ⢠See tables
Load
Temperature
Coefficient
⢠±0.02/°C max
General
Efficiency
Isolation
Isolation Capacitance
Switching Frequency
MTBF
⢠See tables
⢠1500 VDC Input to Output
1000 VDC Input to Case
1000 VDC Output to Case
⢠1000 pF max
⢠330 kHz typical
⢠>1.1 MHrs to MIL-STD-217F
Environmental
Operating Temperature ⢠-40 ºC to +100 ºC, derate from 100% load
at +60 °C to no load at +100 °C
Case Temperature
⢠+100 ºC max
Storage Temperature ⢠-40 ºC to +125 ºC
Humidity
⢠Up to 90%, non-condensing
Cooling
⢠Natural convection
EMC
Emissions
ESD Immunity
Radiated Immunity
EFT/Burst
Surge
Conducted Immunity
Magnetic Field
⢠EN55022 Class A conducted with external
components - see application note
⢠EN61000-4-2,
4 kV contact discharge Perf Criteria B
⢠EN61000-4-3, 3 V/m Perf Criteria A
⢠EN61000-4-4, level 3 Perf Criteria B*
⢠EN61000-4-5, level 3 Perf Criteria B*
⢠EN61000-4-6, 3 Vrms Perf Criteria A
⢠EN61000-4-8, 1 A/m Perf Criteria A
* See note 5.
|
▷ |