JCF1024S2V5 Datasheet, PDF (1/2 Pages) XP Power Limited – DC-DC Power Supplies | |||
|
10 Watts
JCF10 Series
xppower.com
⢠2:1 Input Range
⢠DIP-24 Metal Package
⢠Operating Temperature -40 °C to +100 °C
⢠High Efficiency up to 89%
⢠1500 VDC Isolation
⢠Input Pi Filter
⢠Continuous Short Circuit Protection
Specification
Input
General
Input Voltage Range
Input Current
Input Filter
Undervoltage Lockout
⢠24 V (18-36 VDC)
48 V (36-75 VDC)
⢠See table
⢠Pi network
⢠Turn on >71% nominal input
Turn off <67% nominal input
Efficiency
Isolation Voltage
Switching Frequency
MTBF
⢠See table
⢠1500 VDC min
⢠380 kHz typical
⢠1,000 kHrs min per MIL-HDBK-217F
Environmental
Output
Output Voltage
⢠See table
Minimum Load
⢠None
Line Regulation
⢠±0.2%
Load Regulation
⢠±0.5%
Setpoint Accuracy
⢠±1.0%
Ripple & Noise
⢠75 mV pk-pk, 20 MHz BW
Transient Response
⢠±5% deviation recovery to within 1% in
<500 µs for a 25% step load change
Temperature
Coefficient
⢠±0.05%/°C
Overvoltage Protection ⢠On single output models only
2.5 V models: 3.9 V typical,
3.3 V models: 3.9 V typical,
5.0 V models: 6.2 V typical,
12.0 V models: 15.0 V typical
Overcurrent Protection ⢠110-140%
Short Circuit Protection ⢠Trip & restart (Hiccup mode), auto recovery
Operating Temperature ⢠-40 °C to +100 °C (see derating curve)
Case Temperature
⢠+100 °C max
Storage Temperature ⢠-40 °C to +125 °C
Cooling
⢠Convection-cooled
Operating Humidity ⢠Up to 95% RH, non-condensing
Shock
⢠30 g, half sine wave 18 ms pulse applied
3 times on each of 6 axes
Vibration
⢠5-500 Hz, 3 g, for 10 mins on each
of 3 axes
EMC
Emissions
ESD Immunity
Radiated Immunity
Conducted Immunity
⢠EN55022, Level A conducted & radiated
with external components (contact
technical sales for details)
⢠EN61000-4-2, Level 2 Perf Criteria A
⢠EN61000-4-3, 3 V/m Perf Criteria A
⢠EN61000-4-6, 3 V rms Perf Criteria A
|
▷ |