JCD0624D09 Datasheet, PDF (1/2 Pages) XP Power Limited – Industry Standard Package | |||
|
6 Watts
JCD Series
xppower.com
⢠2:1 Input Range
⢠Industry Standard Package
⢠1600 VDC Isolation
⢠Continuous Short Circuit Protection
⢠40 °C to +100 °C Operating Temperature
⢠Single & Dual Outputs
⢠3 Year Warranty
Specification
Input
General
Input Voltage Range
Input Current
Input Reflected
Ripple Current
Input Filter
Input Surge
Output
Output Voltage
Setpoint Accuracy
Voltage Balance
Minimum Load
Line Regulation
⢠5 V (4.5-9 VDC)
Efficiency
⢠See table
12 V (9-18 VDC)
Isolation Voltage
⢠1600 VDC Input to Output
24 V (18-36 VDC)
For optional high isolation versions
48 V (36-72 VDC)
⢠See table
Y ⢠35 mA rms through 12 µH inductor
R ⢠Pi network
A ⢠5 V models 15 VDC for 100 ms
12 V models 24 VDC for 100 ms
IN 24 V models 40 VDC for 100 ms
48 V models 80 VDC for 100 ms
IM ⢠See table
L ⢠±1% (±2% for JCD0612/24/48S3V3
& D03 models)
E ⢠±1% (±2% D03 models)
R ⢠No minimum load required
P⢠±0.5%
Isolation Capacitance
Isolation Resistance
Switching Frequency
Power Density
MTBF
3500 VDC Input to Output add suffix -H to
model number
1600 VDC Input to Case
1600 VDC Output to Case
⢠500 pF typical input to output
⢠109â¦
⢠266 kHz typical
⢠15 W/in3
⢠>1.1 MHrs to MIL-STD-217F at 25 °C, GB
Environmental
Operating Temperature ⢠-40 °C to +100 °C (see derating curve)
Case Temperature
⢠+100 °C max
Storage Temperature ⢠-40 °C to +125 °C
Cooling
⢠Convection-cooled
Operating Humidity ⢠Up to 95% RH, non-condensing
Load Regulation
⢠±0.5% single outputs, ±1.5% for S3V3 &
D03 models
EMC
Cross Regulation
Ripple & Noise
Start Up Delay
⢠±5% (see note 1)
⢠60 mV pk-pk, 20 MHz bandwidth
⢠20 ms typical for 5 V input models,
500 ms typical for 12/24/48 V input
models
Emissions
ESD Immunity
Radiated Immunity
EFT/Burst
⢠EN55022 Class A conducted with external
components, see application note
⢠EN61000-4-2, level 3, Perf Criteria B
⢠EN61000-4-3, 10 V/m, Perf Criteria A
⢠EN61000-4-4, level 3 Perf Criteria B*
Transient Response
⢠3% max deviation, recovery to within 1%
in 250 µs (5% & 300 µS for
JCD0612/24/48S3V3 & D03 models) for a
25% load change
Surge
Conducted Immunity
Magnetic Field
⢠EN61000-4-5, level 2, Perf Criteria B*
⢠EN61000-4-6, 10 Vrms, Perf Criteria A*
⢠EN61000-4-8, 1 A/m, Perf Criteria A*
Temperature
Coefficient
Overload Protection
⢠0.02%/°C
⢠150% of full load on 5 V input models only
*External input capacitor required, 220 µF/100 V
Short Circuit Protection ⢠Indefinite with auto recovery
Maximum Capacitive ⢠See table
Load
|
▷ |