English
Language : 

JCD0624D09 Datasheet, PDF (1/2 Pages) XP Power Limited – Industry Standard Package
6 Watts
JCD Series
xppower.com
• 2:1 Input Range
• Industry Standard Package
• 1600 VDC Isolation
• Continuous Short Circuit Protection
• 40 °C to +100 °C Operating Temperature
• Single & Dual Outputs
• 3 Year Warranty
Specification
Input
General
Input Voltage Range
Input Current
Input Reflected
Ripple Current
Input Filter
Input Surge
Output
Output Voltage
Setpoint Accuracy
Voltage Balance
Minimum Load
Line Regulation
• 5 V (4.5-9 VDC)
Efficiency
• See table
12 V (9-18 VDC)
Isolation Voltage
• 1600 VDC Input to Output
24 V (18-36 VDC)
For optional high isolation versions
48 V (36-72 VDC)
• See table
Y • 35 mA rms through 12 µH inductor
R • Pi network
A • 5 V models 15 VDC for 100 ms
12 V models 24 VDC for 100 ms
IN 24 V models 40 VDC for 100 ms
48 V models 80 VDC for 100 ms
IM • See table
L • ±1% (±2% for JCD0612/24/48S3V3
& D03 models)
E • ±1% (±2% D03 models)
R • No minimum load required
P• ±0.5%
Isolation Capacitance
Isolation Resistance
Switching Frequency
Power Density
MTBF
3500 VDC Input to Output add suffix -H to
model number
1600 VDC Input to Case
1600 VDC Output to Case
• 500 pF typical input to output
• 109Ω
• 266 kHz typical
• 15 W/in3
• >1.1 MHrs to MIL-STD-217F at 25 °C, GB
Environmental
Operating Temperature • -40 °C to +100 °C (see derating curve)
Case Temperature
• +100 °C max
Storage Temperature • -40 °C to +125 °C
Cooling
• Convection-cooled
Operating Humidity • Up to 95% RH, non-condensing
Load Regulation
• ±0.5% single outputs, ±1.5% for S3V3 &
D03 models
EMC
Cross Regulation
Ripple & Noise
Start Up Delay
• ±5% (see note 1)
• 60 mV pk-pk, 20 MHz bandwidth
• 20 ms typical for 5 V input models,
500 ms typical for 12/24/48 V input
models
Emissions
ESD Immunity
Radiated Immunity
EFT/Burst
• EN55022 Class A conducted with external
components, see application note
• EN61000-4-2, level 3, Perf Criteria B
• EN61000-4-3, 10 V/m, Perf Criteria A
• EN61000-4-4, level 3 Perf Criteria B*
Transient Response
• 3% max deviation, recovery to within 1%
in 250 µs (5% & 300 µS for
JCD0612/24/48S3V3 & D03 models) for a
25% load change
Surge
Conducted Immunity
Magnetic Field
• EN61000-4-5, level 2, Perf Criteria B*
• EN61000-4-6, 10 Vrms, Perf Criteria A*
• EN61000-4-8, 1 A/m, Perf Criteria A*
Temperature
Coefficient
Overload Protection
• 0.02%/°C
• 150% of full load on 5 V input models only
*External input capacitor required, 220 µF/100 V
Short Circuit Protection • Indefinite with auto recovery
Maximum Capacitive • See table
Load