JCB03 Datasheet, PDF (1/2 Pages) XP Power Limited – 3 Watts JCB Series | |||
|
3 Watts
JCB Series
xppower.com
⢠2:1 Input Range
⢠Operating Temperature 40 °C to +100 °C
⢠Single & Dual Outputs
⢠1500 VDC Isolation
⢠Optional Isolation to 3000 VDC
⢠Optional Metal Case
⢠3 Year Warranty
Specification
Input
Input Voltage Range
Input Current
Input Filter
Input Reflected Ripple
Input Surge
Undervoltage Lockout
Reverse Voltage
Protection
⢠5 V (4.5-9 VDC)
12 V (9-18 VDC)
24 V (18-36 VDC)
48 V (36-72 VDC)
⢠See table
⢠Pi network
⢠35 mA pk-pk through 12 µH inductor
⢠5 V models 15 VDC for 100 ms
12 V models 24 VDC for 100 ms
24 V models 40 VDC for 100 ms
48 V models 80 VDC for 100 ms
⢠None
⢠None
Output
Output Voltage
⢠See table
Minimum Load
⢠Minimum load required (see note 1)
Initial Set Accuracy ⢠±1% max
Line Regulation
⢠±0.5% max
Load Regulation
⢠±0.5% max
Cross Regulation
⢠±5% on dual output models (see note 2)
Transient Response
⢠<3% deviation, recovery to within 1% in
2 ms for a 50% load change
Ripple & Noise
⢠60 mV pk-pk max, 20 MHz bandwidth
Short Circuit Protection ⢠Continuous, with auto recovery
Overvoltage Protection ⢠None
Overcurrent Protection ⢠None
Maximum Capacitive ⢠See tables
Load
Temperature
Coefficient
⢠±0.02/°C max
General
Efficiency
Isolation Voltage
Switching Frequency
Isolation Resistance
Power Density
MTBF
⢠See tables
⢠1500 VDC Input to Output
For optional high isolation version 3000 VDC
(see note 3)
1500 VDC Input to Case
1500 VDC Output to Case
⢠100-400 kHz variable
⢠109 â¦
⢠7.5 W/in3
⢠>2 MHrs to MIL-HDBK-217F at 25 °C, GB
Environmental
Operating Temperature ⢠-40 °C to +100 °C, derate from 100% load
at +85 °C to no load at +100 °C
Case Temperature
⢠+100 °C max
Storage Temperature ⢠-40 °C to +125 °C
Humidity
⢠Up to 95% RH, non-condensing
Cooling
⢠Natural convection
EMC & Safety
Emissions
ESD Immunity
EFT/Burst
Surge
Conducted Immunity
Magnetic Fields
⢠EN55022 Class A conducted &
radiated, with external components,
see application note
⢠EN61000-4-2, level 3, Perf Criteria A
⢠EN61000-4-4, level 3, Perf Criteria A
(see note 7)
⢠EN61000-4-5, installation class 3,
Perf Criteria A (see note 7)
⢠EN61000-4-6, 10 V rms, Perf Criteria A
⢠EN61000-4-8, 1 A/m, Perf Criteria A
|
▷ |