English
Language : 

JCA04 Datasheet, PDF (1/2 Pages) XP Power Limited – 4/6 Watts JCA Series
4/6 Watts
JCA Series
xppower.com
• Compact 1.0”x 0.8”Metal Package
• Industry Standard Pin Out
• 2:1 Input Range
• Single & Dual Outputs
• Operating Temperature -40 °C to +100 °C
• UL & TUV Approved
• 3 Year Warranty
Specification
Input
Input Voltage Range
Input Current
Input Filter
Input Surge
Input Reflected Ripple
• 5 V (4.5-9.0 VDC), 12 V (9-18 VDC)
24 V (18-36 VDC), 48 V (36-75 VDC)
• See table
• Pi network
• 5 V models 10 V for 1 s max,
12 V models 25 V for 1 s max,
24 V models 50 V for 1 s max,
48 V models 100 V for 1 s max
• 80 mA for 5 V models
30 mA for all other models
Output
Output Voltage
• See table
Initial Set Accuracy • ±1% max
Start Up Delay
• 200 ms max
Start Up Rise Time
• 3.5 ms typical
Minimum Load
• No minimum load required
Line Regulation
• ±0.3%
Load Regulation
• ±1%
Cross Regulation
• ±5% on dual output models
Transient Response
• 4% max deviation, recovery to within
1% in <500 µs for a 25% load change
at 1 A/µs
Ripple & Noise
• 50 mV pk-pk, 20 MHz bandwidth
Overcurrent Protection • 150% typical, trip & restart
(hiccup mode)
Short Circuit Protection • Continuous with auto recovery
Overvoltage Protection • 150% typical, Recycle input to reset
Temperature
Coefficient
• ±0.05%/°C
General
Efficiency
Isolation
Switching Frequency
Power Density
MTBF
• See table
• 1500 VDC Input to Output, basic insulation
500 VDC Input to Case
500 VDC Output to Case
• 300 kHz typical
• JCA04: 12.5 W/in3, JCA06: 18.8 W/in3
• 1.0 MHrs to MIL-HDBK-217F at 25 °C, GB
Environmental
Operating Temperature • -40 °C to +100 °C output power derates
from 100% load at +75 °C linearly to
0% load at +100 °C
Case Temperature
• +100 °C max
Storage Temperature • -55 °C to +125 °C
Cooling
• Convection cooled
Operating Humidity • Up to 95% RH, non-condensing
EMC & Safety
Emissions
ESD Immunity
Radiated Immunity
Conducted Immunity
Magnetic Fields
Safety Approvals
• EN55022, level A conducted & radiated
(level B with external components,
see application note)
• EN61000-4-2, level 2 Perf Criteria A
• EN61000-4-3 3 V/m Perf Criteria A
• EN61000-4-6 3 V rms Perf Criteria A
• EN61000-4-8, 10 A/m, Perf Criteria A
• EN60950-1, UL60950-1,
CSA C22.2 No. 60950-1-03,
CE Mark LVD