English
Language : 

JAH0212S09 Datasheet, PDF (1/2 Pages) XP Power Limited – 2 Watts JAH Series
2 Watts
JAH Series
xppower.com
• Low Cost
• DIP 24 Package
• Operating Temperature 40 °C to +100 °C
• Single & Dual Outputs
• Optional Metal Case
• Optional Isolation to 6000 VDC
• 3 Year Warranty
Specification
Input
Input Voltage Range
Input Current
Input Filter
Input Reverse Voltage
Protection
Undervoltage Lockout
Input Reflected Ripple
Input Surge
• Nominal ±10%
• See table
• Pi network
• None
• None
• 35 mA pk-pk through 12 µH inductor,
5 Hz to 20 MHz
• 5 V models 7 VDC for 100 ms
12 V models 15 VDC for 100 ms
24 V models 28 VDC for 100 ms
Output
Output Voltage
• See table
Minimum Load
• No minimum load required
Initial Set Accuracy • ±2% max
Start Up Delay
• 20 ms typical
Start Up Rise Time
• 20 ms typical
Line Regulation
• ±0.5% max
Load Regulation
• ±0.5% max single & dual models
(±1.0% max for 3V3 versions) (see note 6)
Cross Regulation
• ±5% on dual output models (see note 4)
Transient Response
• ±3% max deviation (±5% for 3V3 output),
recovery to within 1% in 2 ms for a 50%
load change
Ripple & Noise
• 75 mV pk-pk measured with
20 MHz bandwidth
Short Circuit Protection • Output shuts down with auto recovery
Maximum Capacitive • See tables
Load
Temperature
Coefficient
• ±0.02/°C max
General
Efficiency
Isolation
Isolation Resistance
Switching Frequency
Power Density
MTBF
• See tables
• 1000 VDC input to output, for optional
high isolation versions up to 6000 VDC
input to output (see note 1)
1000 VDC input to case
1000 VDC output to case
• 109Ω
• 40 kHz typical singles,
300 kHz typical duals
• 5.21 W/in3
• >3 MHrs to MIL-HDBK-217F at 25 °C, GB
Environmental
Operating Temperature • -40 °C to +100 °C, derate from 100% load
at +85 °C to no load at +100 °C
Case Temperature
• +100 °C max
Storage Temperature • -40 °C to +125 °C
Humidity
• Up to 90%, non-condensing
Cooling
• Natural convection
EMC & Safety
Emissions
ESD Immunity
EFT/Burst
Surge
Conducted Immunity
Magnetic Fields
• EN55022 class A, conducted & radiated
with external components
(see Application Notes)
• EN61000-4-2, level 3, Perf Criteria A
• EN61000-4-4, level 3, Perf Criteria A
(see note 5)
• EN61000-4-5, installation class 2,
Perf Criteria A (see note 5)
• EN61000-4-6, 10 Vrms, Perf Criteria A
• EN61000-4-8, 1 A/m, Perf Criteria A