165 Watts
IFC165 Series
xppower.com
• Small Size - 3.0” x 5.0” x 1.25”
• High Power Density
• Active PFC Meets EN61000-3-2, -3
• Single, Dual, Triple & Quad Outputs
• High Efficiency - up to 90%
• Overvoltage and Overcurrent Protection
• Power Fail Detect
Specification
Input
Input Voltage
Input Frequency
Input Current
Inrush Current
Power Factor
Earth Leakage Current
Input Protection
• 90-264 VAC
• 47-63 Hz
• 2.2 A max at 100 VAC
• 33 A at 115 VAC, 66 A at 230 VAC
• 0.90 minimum
• 0.75 mA max at 240 VAC
• Internal 3.15 A fuse
Output
Output Voltage
• See table
Output Voltage Trim • Not user adjustable
Initial Set Accuracy • ±5% maximum
Minimum Load
• 5 W minimum load required
Start Up Delay
• 1.5 s max at 90 VAC
Start Up Rise Time
• 0.2-20 ms
Hold Up Time
• 22 ms min
Line Regulation
• See table and note 1
Load Regulation
• See table and note 2
Over/Undershoot
• <10% at turn on/off
Transient Response
• 5% max. deviation, recovery to within
1% in 500 µs for a 25% load change
Ripple & Noise
• 1% pk-pk or 50 mV, whichever is greater
Overvoltage Protection • 113-145% Vnom, recycle input to reset
Overtemperature
Protection
• Shuts down at 120˚C, recycle input to
reset
Overcurrent Protection • 150% max, auto recovery (hiccup mode)
Short Circuit Protection • Trip and restart (hiccup mode)
Temperature
Coefficient
• 0.04% / ºC
Remote Sense
• Compensates for up to 0.5 V drop
Current Share
• IFC165PSXX models only - up to
4 supplies to share within 10%
General
Efficiency
Isolation
Switching Frequency
Power Density
Signals
MTBF
• 85% typical
• 3000 VAC Input to Output
1500 VAC Input to Ground
500 VAC Output to Ground
• 86 kHz typical
• 8.8 W/In3
• Power Good - On = Logic High
AC OK - On = Logic Low (PS12, PS24 &
PS48 only)
Green LED for AC OK (PS12, PS24 &
PS48 only)
• 200 kHrs per Bellcore
Environmental
Operating Temperature • -25 ºC to +70 ºC, derate linearly from
100% at 50 ºC to 50% at 70 ºC
Cooling
• 12 CFM airflow required for full power
Operating Humidity • 85% RH, non-condensing
Storage Temperature • -40 ºC to +85 ºC
Operating Altitude
• 3000 m
Shock
• 15 G pk
Vibration
• 2.4 G, 5 Hz to 500 Hz, 3 axis
EMC & Safety
Emissions
Harmonic Currents
Voltage Flicker
Radiated Immunity
EFT/Burst
Surge
Dips & Interruptions
Safety Approvals
• EN55022, level A conducted
• EN61000-3-2
• EN61000-3-3
• EN61000-4-3, level 3 Perf Criteria B
• EN61000-4-4, level 3 Perf Criteria B
• EN61000-4-5, level 3 Perf Criteria B
• EN61000-4-11. 30% 10 ms, 60% 100 ms,
100% 5000ms, Criteria A, B, B
• EN60950, UL60950, CSA950 per cUL
1