IFC125 Datasheet, PDF (1/2 Pages) XP Power Limited – Triple and Quad Outputs | |||
|
125 Watts
IFC125 Series
xppower.com
⢠Small Size 3.0â x 5.0â x 1.25â
⢠Triple and Quad Outputs
⢠Active PFC Meets EN61000 3 2, 3
⢠Overvoltage & Overcurrent Protection
⢠Power Good Signal
⢠25 °C to +50 °C Full Power
⢠3 Year Warranty
Specification
Input
Input Voltage
Input Frequency
Input Current
Inrush Current
Power Factor
Earth Leakage Current
Input Protection
⢠90-264 VAC
⢠47-63 Hz
⢠0.8 A max at 240 VAC
1.8 A max at 100 VAC
⢠33 A max at 115 VAC
66 A max at 230 VAC
⢠0.98 typical
⢠0.5 mA max at 132 VAC/60Hz
0.825 mA max at 264 VAC/50Hz
⢠Internal 2.6 A fuse
Output
Output Voltage
⢠See table
Output Voltage Trim ⢠Not user-adjustable
Initial Set Accuracy ⢠±5% maximum
Minimum Load
⢠5 W minimum load on V1 or V2 required
to maintain regulation
Start Up Delay
⢠1.5 s at 90 VAC
Start Up Rise Time
⢠0.2-20 ms
Hold Up Time
⢠>28 ms min at full load
Line Regulation
⢠See table
Load Regulation
⢠See table
Over/Undershoot
⢠10% maximum
Transient Response
⢠5% max. deviation, recovery to within
1% in 500 µs for a 25% load change
Ripple & Noise
⢠±1% pk-pk maximum or â¤5 Vout 50 mV
maximum
Overvoltage Protection ⢠V1 & V2: 113-148%, auto recovery
Overtemperature
Protection
⢠Unit shuts down, recycle input to reset
Overload Protection ⢠All outputs: 115-135%, auto recovery
Short Circuit Protection ⢠Trip and restart (Hiccup mode)
Temperature
Coefficient
⢠0.04% / ËC maximum
Remote Sense
⢠V1 only compensates for 0.5 V drop (not
available on IFC125-31)
General
Efficiency
Isolation
Power Density
Signals
MTBF
⢠83% typical
⢠3000 VAC Input to Output
1500 VAC Input to Ground
500 VAC Output to Ground
⢠6.66 W/In3
⢠Power Good - On = Logic High
⢠>220 kHrs per Bellcore
Environmental
Operating Temperature ⢠-25 ËC to +70 ËC, derate linearly from
100% at +50 ËC to 50% at +70 ËC
Cooling
⢠5 CFM airflow required for 125 W
Operating Humidity ⢠5-95% RH, non-condensing
Storage Temperature ⢠-40 ËC to +85 ËC
Operating Altitude
⢠3000 m
Shock
⢠15 G pk operating
Vibration
⢠2.4 G, 5 Hz to 500 Hz, 3 axis
EMC & Safety
Emissions
Harmonic Currents
Voltage Flicker
Radiated Immunity
EFT/Burst
Surge
Conducted Immunity
Dips & Interruptions
Safety Approvals
⢠EN55022/CISPR22 and FCC, Class
B conducted
⢠EN61000-3-2
⢠EN61000-3-3
⢠EN61000-4-3, level 3 Perf Criteria B
⢠EN61000-4-4, level 3 Perf Criteria B
⢠EN61000-4-5, level 3 Perf Criteria B
⢠EN61000-4-6
⢠EN61000-4-11, 30% 10 ms, 60% 100 ms,
100% 5000 ms, Criteria A, B, B
⢠EN60950, UL 60950, CSA950 per cUL,
CE Mark LVD
|
▷ |