English
Language : 

IF0503S Datasheet, PDF (1/1 Pages) XP Power Limited – DC-DC Power Supplies
1 Watt
IF Series
xppower.com
• Regulated Single Output
• Industry Standard Pinout
• SIP or DIP Package
• Low Ripple & Noise
• 1000 VDC Isolation
• Optional 3000 VDC Isolation
• MTBF >4 MHrs
Specification
Input
Input Voltage Range
Input Reflected Ripple
Input Reverse Voltage
Protection
• Nominal ±10%
• 20 mA pk-pk through 12 µH inductor,
5 Hz to 20 MHz
• None
Output
Output Voltage
• See table
Minimum Load
• None(4)
Line Regulation
• ±0.5% max
Load Regulation
• ±0.5% max (±1.0% for 3.3 V output)
Setpoint Accuracy
• ±2% max
Ripple & Noise
• 50 mV pk-pk max, 20 MHz BW
Temperature Coefficient • 0.02%/°C
Short Circuit Protection • 1 sec
Maximum Capacitive • 220 µF
Load
General
Input
Voltage
5V
12 V
24 V
Output
Voltage
3.3 V
5.0 V
9.0 V
12.0 V
15.0 V
3.3 V
5.0 V
9.0 V
12.0 V
15.0 V
3.3 V
5.0 V
9.0 V
12.0 V
15.0 V
Output
Current
333 mA
200 mA
111 mA
84 mA
67 mA
333 mA
200 mA
111 mA
84 mA
67 mA
333 mA
200 mA
111 mA
84 mA
67 mA
Mechanical Details
0.76
(19.50)
Efficiency
57%
65%
65%
68%
68%
57%
63%
66%
68%
70%
60%
65%
68%
68%
68%
Model
Number(1,2)
IF0503S
IF0505S
IF0509S
IF0512S
IF0515S
IF1203S
IF1205S
IF1209S
IF1212S
IF1215S
IF2403S
IF2405S
IF2409S
IF2412S
IF2415S
0.28
(7.20)
Efficiency
Isolation Voltage
Resistance
Isolation Capacitance
Switching Frequency
MTBF
• See table
• 1000 VDC standard,
3000 VDC option - see note 2
• 1000 MΩ min
• 60 pF typical
• 50 kHz typical
• >4 MHrs
Environmental
SIP
0.37
Package (9.50)
0.39
(10.00)
0.02
(0.50)
0.12
(3.05)
0.10 (2.54)
0.60
Pin
1
(15.24)
2
0.01
(0.25)
12
4
4 5 6 7 0.28 (7.20) 5
6
0.02
7
(0.50)
0.08
(2.00)
Standard
+Vin
-Vin
-Vout
No Pin
+Vout
No Pin
‘-H’ Version
+Vin
-Vin
No Pin
-Vout
No Pin
+Vout
Operating Temperature • -40 °C to +85 °C (no derating)
Storage Temperature • -40 °C to +125 °C
Case Temperature
• +100 °C max
Cooling
• Convection-cooled
Notes
DIP
Package
0.80
(20.32)
0.40
(10.16)
0.12
(3.05)
0.40
(10.16 )
0.27 (6.85)
1. For DIP package, replace suffix ‘S’ with suffix ‘D’.
2. For 3000 VDC isolation, add suffix ‘-H’.
3. All dimensions in inches (mm).
4. Operation at no load will not damage unit but it may not meet all specifications.
1
0.30
(7.62)
14
0.60
(15.24)
7
11 10 9 8
0.30
(7.62)
Pin
1
7
8
0.01
(0.25)
9
10
11
0.02 14
(0.50)
Standard
-Vin
N.C.
No Pin
+Vout
No Pin
-Vout
+Vin
‘-H’ Version
-Vin
N.C.
+Vout
No Pin
-Vout
No Pin
+Vin
04-Apr-08