HDS800 Datasheet, PDF (1/4 Pages) XP Power Limited – 1U Profile, High Power Density | |||
|
800 Watts
HDS800 Series
xppower.com
⢠High Efficiency up to 92%
⢠1U Profile, High Power Density
⢠Programmable Output Voltage (0-105%)
⢠Programmable Output Current (0-105%)
⢠Parallel Operation
⢠Fully Featured Signals & Controls
⢠3 Year Warranty
Specification
Input
General
Input Voltage
Input Frequency
Input Current
Inrush Current
Power Factor
Earth Leakage Current
Input Protection
⢠90-264 VAC (127-370 VDC),
see derating curve
⢠47-63 Hz
⢠9.3 A/3.7 A typical at 100/240 VAC
⢠30.0 A/60.0 A typical at 115/230 VAC
⢠0.98/0.95, typical at 115/230 VAC full load
⢠<1.0 mA at 264 VAC/60 Hz
⢠T or F15 A/250 V internal fuse
Output
Efficiency
Isolation
Switching Frequency
Power Density
Signals & Controls
MTBF
⢠See model table
⢠3000 VAC Input to Output,
1500 VAC Input to Ground,
500 VAC Output to Ground
⢠PFC 65 kHz typical, PWM 40-200 kHz
variable
⢠10.1 W/in3
⢠Enable, Current Share, V Program,
I Program, 5 V Standby, PWM switching
⢠90 kHrs to MIL-HDBK-217F at 25 ËC
Output Voltage
⢠See model table
Output Trim
⢠±5.0% by potentionmeter
Output Voltage Program ⢠0-105% of rated output
Output Current Program ⢠0-105% of rated output
Initial Set Accuracy ⢠±1%
Minimum Load
⢠No minimum load required
Start Up Delay
⢠800 ms maximum
Start Up Rise Time
⢠100 ms maximum at full load
Hold Up Time
⢠8 ms minimum
Line Regulation
⢠±1%
Load Regulation
⢠V1: ±1%, standby output: ±3%
Environmental
Operating Temperature ⢠-20 ËC to 70 ËC, derate linearly from 100%
load at 50 ËC to 50% load at 70 ËC
Cooling
⢠Internal fan fitted. Speed increases with load
and internal temperature
Operating Humidity ⢠20-90% R.H. non-condensing
Storage Temperature ⢠-40 ËC to +85 ËC
Storage Humidity
⢠10-95% R.H.
Vibration
⢠10-500 Hz, 2g 10 min/cycle, 60 min
period for each axis. Compliant to
IEC68-2-16, IEC 68-2-64
Transient Response
Ripple & Noise
⢠<1% for a 25% step load change
⢠150 mV pk-pk all voltages, see note 1
EMC & Safety
Overvoltage Protection ⢠Tracks output voltage. See application
notes, Recycle AC to reset
Emissions
Harmonic Currents
⢠EN55022 class B conducted & radiated
⢠EN61000-3-2 class A
Overtemperature
Protection
Overload Protection
⢠Primary and secondary heatsinks monitored. Voltage Flicker
Output shuts down, auto recovers
ESD Immunity
⢠>105% rated power, constant current
⢠EN61000-3-3
⢠EN61000-4-2, ±4 kV contact,
±8 kV air discharge, Perf Criteria A
Short Circuit Protection ⢠Auto recovery
Radiated Immunity
⢠EN61000-4-3, 3 V/m, Perf Criteria A
Temperature
Coefficient
Remote Sense
⢠±0.02%/ËC (0-50 ËC)
⢠Compensates for 0.5 V max voltage drop
If remote sense is not required, local sense
must be used
EFT/Burst
Surge
Conducted Immunity
Magnetic Field
⢠EN61000-4-4, level 2, Perf Criteria A
⢠EN61000-4-5, installation class 3,
Perf Criteria A
⢠EN61000-4-6, 3 V, Perf Criteria A
⢠EN61000-4-8, 1 A/m, Perf Criteria A
Enable
Current Share
⢠Output must be enabled. See application
notes, power supply is shipped with enable
links fitted
⢠5 supplies can share within 5%
Dips & Interruptions
Safety Approvals
⢠EN55024, >95% 10 ms, 30% 500 ms,
>95% 5000 ms, Perf Criteria A, A, B
⢠UL60950-1, CSA C22.2 No. 60950-1,
EN60950-1
Standby Output
⢠5 V at 0.5 A, present whenever AC is applied
(9V at 0.3A, user selectable, by connecting
âVSETâ, Pin 18 of CN2 to âGNDâ)
|
▷ |