650 3000 Watts
HCP Series
xppower.com
• High Efficiency up to 91%
• High Power Density
• Programmable Output Voltage (30% 105%)
• Programmable Output Current (40% 105%)
• Parallel Operation
• Fully Featured Signals & Controls
• 3 Year Warranty
Specification
Input
Input Voltage
Input Frequency
Input Current
Inrush Current
Power Factor
Earth Leakage Current
• 90-264 VAC (127-370 VDC),
see derating curves
• 47-63 Hz
• 650 W: 7.5 A/3.5 A typical,
1000 W: 12 A/5 A typical,
1500 W: 18 A/9 A typical,
3000 W: 36 A/18 A typical at 115/230 VAC
• 650/1000 W: 27 A/54 A typical
1500 W: 30 A/45 A typical
3000 W: 60 A/90 A typical at 115/230 VAC
• 0.99/0.98, typical at 115/230 VAC full load
• <1.0 mA (3 kW: <2.5 mA) at 240VAC/60 Hz
Output
Output Voltage
• See model table
Output Trim
• ±5.0% by potentiometer
Output Voltage Program• 30-105% of rated output (see app. notes)
Output Current Program • 40-105% of rated output (see app. notes)
Initial Set Accuracy • ±1%
Minimum Load
• No minimum load required
Start Up Delay
• 650 W/1000 W: 800 ms max.
1500 W/3000 W: 1 s max.
Start Up Rise Time
• 650 W: 90 ms max. at full load
1000 W: 100 ms max. at full load
1500 W/3000 W: 350 ms max. at full load
Hold Up Time
• 16 ms (3000 W: 20 ms) typ. at 230 VAC
and full load
Line Regulation
• ±0.5%
Load Regulation
• V1: ±0.5%, 5 V standby output: ±3%
Transient Response • <1% for a 25% step load change
Ripple & Noise
• 150 mV pk-pk all voltages (see note 1)
Overvoltage Protection • Tracks output voltage. 115-135% of set
voltage. Recycle AC to reset
Overtemperature
Protection
• Auto recovery
Overload Protection
• 105-125% of output power. Constant
power to 75% of set output voltage then
output shuts down, recycle AC to reset
Short Circuit Protection • Output latches off, recycle AC to reset
Temp. Coefficient
• ±0.02%/˚C (0-50 ˚C)
Remote Sense
• Compensates for 0.5 V max voltage drop.
(see app. notes)
Enable
• Output must be enabled (see app. notes)
Current Share
• 5 supplies can share within 5%
Standby Output
• See model table
General
Efficiency
Isolation
Isolation Resistance
Switching Frequency
Power Density
Signals & Controls
MTBF
• See model table
• 3000 VAC Input to Output,
1500 VAC Input to Ground,
500 VDC Output to Ground
• 100 M /500 VDC
• PFC 100 kHz typical, PWM 65 kHz typical
• 650 W: 8.2 W/in3
1000 W: 11.1 W/in3
1500 W/3000 W: 10.8 W/in3
• See app. notes
• 650 W: 160 kHrs, 1000 W: 140 kHrs,
1500 W/3000 W: 100 kHrs
to MIL-HDBK-217F at 25 ˚C, GB
Environmental
Operating Temperature • -25 ˚C to 60 ˚C, see derating curves
Cooling
• Internal fan fitted. Speed increases with
load and internal temperature
Operating Humidity • 20-90% R.H. non-condensing
Storage Temperature • -40 ˚C to +85 ˚C
Storage Humidity
• 10-95% R.H.
Vibration
• 10-500 Hz, 5 g 10 min/cycle, 60 min
period for each axis. Compliant to
IEC68-2-16, IEC 68-2-64
EMC & Safety
Emissions
Harmonic Currents
Voltage Flicker
ESD Immunity
Radiated Immunity
EFT/Burst
Surge
Conducted Immunity
Magnetic Field
Dips & Interruptions
Safety Approvals
• EN55022 class B conducted & radiated
• EN61000-3-2 class A,
650 & 1000 W: EN61000-3-2 class C for
loads ≥10%,
1500 W: EN61000-3-2 class C for loads ≥40%,
3000 W: EN61000-3-2 class C for loads ≥30%
• EN61000-3-3
• EN61000-4-2, ±4 kV contact,
±8 kV air discharge, Perf Criteria A
• EN61000-4-3, 3 V/m, Perf Criteria A
• EN61000-4-4, level 2, Perf Criteria A
• EN61000-4-5, installation class 3,
Perf Criteria A
• EN61000-4-6, Perf Criteria A
• EN61000-4-8, Perf Criteria A
• EN61000-4-11, 30% 10 ms, 60% 100 ms,
>95% 5000 ms, Perf Criteria A, B, B
• UL60950-1, EN60950-1 (all models)
CSA C22.2 No. 60950-1 (650 W/1000 W only)