HCP650 Datasheet, PDF (1/8 Pages) XP Power Limited – 650-3000 Watts HCP Series | |||
|
650 3000 Watts
HCP Series
xppower.com
⢠High Efficiency up to 91%
⢠High Power Density
⢠Programmable Output Voltage (30% 105%)
⢠Programmable Output Current (40% 105%)
⢠Parallel Operation
⢠Fully Featured Signals & Controls
⢠3 Year Warranty
Specification
Input
Input Voltage
Input Frequency
Input Current
Inrush Current
Power Factor
Earth Leakage Current
⢠90-264 VAC (127-370 VDC),
see derating curves
⢠47-63 Hz
⢠650 W: 7.5 A/3.5 A typical,
1000 W: 12 A/5 A typical,
1500 W: 18 A/9 A typical,
3000 W: 36 A/18 A typical at 115/230 VAC
⢠650/1000 W: 27 A/54 A typical
1500 W: 30 A/45 A typical
3000 W: 60 A/90 A typical at 115/230 VAC
⢠0.99/0.98, typical at 115/230 VAC full load
⢠<1.0 mA (3 kW: <2.5 mA) at 240VAC/60 Hz
Output
Output Voltage
⢠See model table
Output Trim
⢠±5.0% by potentiometer
Output Voltage Program⢠30-105% of rated output (see app. notes)
Output Current Program ⢠40-105% of rated output (see app. notes)
Initial Set Accuracy ⢠±1%
Minimum Load
⢠No minimum load required
Start Up Delay
⢠650 W/1000 W: 800 ms max.
1500 W/3000 W: 1 s max.
Start Up Rise Time
⢠650 W: 90 ms max. at full load
1000 W: 100 ms max. at full load
1500 W/3000 W: 350 ms max. at full load
Hold Up Time
⢠16 ms (3000 W: 20 ms) typ. at 230 VAC
and full load
Line Regulation
⢠±0.5%
Load Regulation
⢠V1: ±0.5%, 5 V standby output: ±3%
Transient Response ⢠<1% for a 25% step load change
Ripple & Noise
⢠150 mV pk-pk all voltages (see note 1)
Overvoltage Protection ⢠Tracks output voltage. 115-135% of set
voltage. Recycle AC to reset
Overtemperature
Protection
⢠Auto recovery
Overload Protection
⢠105-125% of output power. Constant
power to 75% of set output voltage then
output shuts down, recycle AC to reset
Short Circuit Protection ⢠Output latches off, recycle AC to reset
Temp. Coefficient
⢠±0.02%/ËC (0-50 ËC)
Remote Sense
⢠Compensates for 0.5 V max voltage drop.
(see app. notes)
Enable
⢠Output must be enabled (see app. notes)
Current Share
⢠5 supplies can share within 5%
Standby Output
⢠See model table
General
Efficiency
Isolation
Isolation Resistance
Switching Frequency
Power Density
Signals & Controls
MTBF
⢠See model table
⢠3000 VAC Input to Output,
1500 VAC Input to Ground,
500 VDC Output to Ground
⢠100 M /500 VDC
⢠PFC 100 kHz typical, PWM 65 kHz typical
⢠650 W: 8.2 W/in3
1000 W: 11.1 W/in3
1500 W/3000 W: 10.8 W/in3
⢠See app. notes
⢠650 W: 160 kHrs, 1000 W: 140 kHrs,
1500 W/3000 W: 100 kHrs
to MIL-HDBK-217F at 25 ËC, GB
Environmental
Operating Temperature ⢠-25 ËC to 60 ËC, see derating curves
Cooling
⢠Internal fan fitted. Speed increases with
load and internal temperature
Operating Humidity ⢠20-90% R.H. non-condensing
Storage Temperature ⢠-40 ËC to +85 ËC
Storage Humidity
⢠10-95% R.H.
Vibration
⢠10-500 Hz, 5 g 10 min/cycle, 60 min
period for each axis. Compliant to
IEC68-2-16, IEC 68-2-64
EMC & Safety
Emissions
Harmonic Currents
Voltage Flicker
ESD Immunity
Radiated Immunity
EFT/Burst
Surge
Conducted Immunity
Magnetic Field
Dips & Interruptions
Safety Approvals
⢠EN55022 class B conducted & radiated
⢠EN61000-3-2 class A,
650 & 1000 W: EN61000-3-2 class C for
loads â¥10%,
1500 W: EN61000-3-2 class C for loads â¥40%,
3000 W: EN61000-3-2 class C for loads â¥30%
⢠EN61000-3-3
⢠EN61000-4-2, ±4 kV contact,
±8 kV air discharge, Perf Criteria A
⢠EN61000-4-3, 3 V/m, Perf Criteria A
⢠EN61000-4-4, level 2, Perf Criteria A
⢠EN61000-4-5, installation class 3,
Perf Criteria A
⢠EN61000-4-6, Perf Criteria A
⢠EN61000-4-8, Perf Criteria A
⢠EN61000-4-11, 30% 10 ms, 60% 100 ms,
>95% 5000 ms, Perf Criteria A, B, B
⢠UL60950-1, EN60950-1 (all models)
CSA C22.2 No. 60950-1 (650 W/1000 W only)
|
▷ |