English
Language : 

GP05US05 Datasheet, PDF (1/2 Pages) XP Power Limited – Universal AC Input Switchers
Universal AC Input Switchers
5-10 Watts
GP Series
THE XPERTS IN POWER
•
85-264 VAC Input
•
Single & Dual Ouptuts
•
PCB Mounting
•
Eurocard Mounting Option
•
DIN Rail Mounting Option
•
Chassis Mounting Option
•
International Safety Approvals
Specification
Input
Input Voltage
Input Frequency
Inrush Current
• 85-264 VAC (110-370 VDC)
• 47-440 Hz
• 20 A typical at 100 VAC,
40 A typical at 200 VAC,
(cold start & full load)
Output
Hold Up Time
•
Output Voltage
•
Line Regulation
•
Load Regulation
•
Ripple & Noise
•
Short Circuit &
•
Overload Protection
10 ms at 85 VAC full load
See Table, ±5% initial tolerance
See Table
See Table
See Table
Operates >105% of rating &
recovers automatically
General
Temperature
•
Coefficient
Switching Frequency •
Efficiency
•
Isolation
•
0.02%/°C typical
250 kHz
See Table
3000 VAC 1 min, 500 VDC 50 Mohm
Input to Output,
2000 VAC 1 min, 500 VDC 50 Mohm
Input to Case, FG
500 VAC 1 min, 500 VDC 50 Mohm
Output to Case, FG
Environmental
Operating
•
Temperature
Humidity
•
Shock
•
Vibration
•
0 °C to +55 °C,
derate linearly to 80% at -10 °C to
25% at +70 °C for 85-132 VAC,
& 45% at +65 °C for 133-264 VAC
20-95% RH non-condensing
50 G for 11 ms, once on each
X, Y & Z axis
10-55 Hz at 10 G, 3 mins period
60 mins each along each along
X, Y & Z axis
EMC & Safety
Safety Approvals
•
EMC
•
IEC950, EN60950, UL1950, VDE 0160,
CSA 22.2 No.234
N.B. To comply with with CSA agency
approval units are labelled with
nominal AC input voltage & frequency
FCC Curve B, VDE 0871 Curve B, &
EN55022B conducted noise with
addition of 0.1 µF ‘X’ capacitor fitted
across AC input
•
www.xpplc.com
•
sales@xpplc.com