EMH250PS12 Datasheet, PDF (1/9 Pages) XP Power Limited – 250/350 Watts EMH Series | |||
|
250/350 Watts
EMH Series
xppower.com
⢠Single & Dual Output Models
⢠IT & Medical (BF) Approvals
⢠80 V 275 VAC Operation
⢠Optional ORing Diode (EMH350D Models)
⢠Analog & PMBus Signals Options (EMH350)
⢠5 V Standby (EMH350)
⢠3 Year Warranty
Specification
Input
Input Voltage
⢠80-275 VAC, derate output power
<90 VAC (see derating curve)
Input Frequency
⢠47-63 Hz
Input Current
⢠2.6 / 3.6 A at 115 VAC typical (250 / 350 W)
1.3 / 1.8 A at 230 VAC typical (250 / 350 W)
Inrush Current
⢠40 A max at 230 VAC, cold start 25 °C
Power Factor
⢠>0.9
Earth Leakage Current ⢠250 µA max, 264 VAC, 60 Hz
Patient Leakage Current ⢠100 µA max
Input Protection
⢠10 AF / 250 V internal fuse in line
and neutral
Output
Output Voltage
⢠12-48 VDC (see tables)
Output Voltage Trim ⢠±10% V1
Initial Set Accuracy ⢠±1% V1, ±5% V2
Minimum Load
⢠No minimum load required
Start Up Delay
⢠1 s typical
Start Up Rise Time
⢠50 ms
Hold Up Time
⢠16 ms typical
Line Regulation
⢠±0.5% maximum
Load Regulation
⢠±1% V1, ±5% standby
Cross Regulation
⢠Dual output only (see regulation curves)
Transient Response
⢠4% max. deviation, recovery to
within 1% in 500 µs for a 50-75-50%
load change
Ripple & Noise
⢠1% pk-pk, 20 MHz bandwidth
Overvoltage Protection ⢠115-140% V1 nom, recycle input to reset
Overtemperature
Protection
⢠Auto reset
Overload Protection ⢠110-150%, power limit
Short Circuit Protection ⢠Continuous, approximately constant
current
Temperature
Coefficient
⢠0.05% /°C
Remote Sense
⢠Compensates for up to 0.5 V drop
General
Efficiency
⢠87% typical
Isolation
⢠4000 VAC input to output 2 x MOPP,
1500 VAC input to ground 1 x MOPP,
1500 VAC output to ground 1 x MOPP
Switching Frequency ⢠62-560 /71 /50-130 KHz,
PFC /Main /Standby Converter
Power Density
⢠11.6/ 16.3/ 9.5 W/in3 (250 / 350 / 350 W Dual)
Signals (Option EMH350) ⢠Power fail, Inhibit, 5 V Standby,
Current Share, fan speed control and I2C
PMBus Options
MTBF
⢠400 kHrs to MIL-HDBK-217F at 25 °C, GB
Environmental
Operating Temperature ⢠0 °C to +70 °C, derate linearly from +50 °C
at 2.5% / °C to 50% load at +70 °C
Cooling
⢠Forced cooled 12 CFM (350 W Dual: 16 CFM)
or integral fan. See thermal considerations
longform datasheet
Operating Humidity ⢠95% RH, non-condensing
Storage Temperature ⢠-40 °C to +85 °C
Operating Altitude
⢠3048 m
Shock
⢠±3 x 30g shocks in each plane, total 18
shocks. 30g = 11 ms (±0.5 ms), half sine,
conforms to EN60068-2-27 & EN60068-2-47
Vibration
⢠Single axis 10 - 500 Hz at 2g sweep and
endurance at resonance in all 3 planes.
Conforms to EN60068-2-6
EMC & Safety
Emissions
Harmonic Currents
Voltage Flicker
Radiated Immunity
EFT/Burst
Surge
Conducted Immunity
Dips & Interruptions
Safety Approvals
⢠EN55011/22 level B conducted
EN55011/22 level A radiated
(See EMC report)
⢠EN61000-3-2, class A
⢠EN61000-3-3
⢠EN61000-4-3, level 3 Perf Criteria A
⢠EN61000-4-4, level 3 Perf Criteria A
⢠EN61000-4-5, installation class 3,
Perf Criteria A
⢠EN61000-4-6, level 3, Perf Criteria A
⢠EN61000-4-11, 30% 10 ms,
60% 100 ms, 100% 5000 ms,
Perf Criteria A, B, B,
EN60601-1-2, 30% 500 ms, 60% 100 ms,
100% 10 ms, 100% 5000 ms, Perf Criteria A,
A, A, B - 230 VAC. Consult longform
datasheet for 115 V operation.
⢠EN60601-1, ANSI/AAMI ES60601-1,
CSA22.2 No.60601-1 per cUL BF Rated,
Including Risk Management, EN60950,
UL60950
|
▷ |