ECP40US05 Datasheet, PDF (1/2 Pages) XP Power Limited – 40 Watts ECP Series | |||
|
40 Watts
ECP Series
xppower.com
⢠Low Profile Design
⢠Ultra Compact Size from 3â x 2â x 0.9â
⢠IT & Medical Approvals
⢠Single, Dual and Triple Output
⢠<0.3 W No Load Input Power
⢠Peak Load Capability
⢠3 Year Warranty
Specification
Input
Input Voltage
Input Frequency
Input Current
Inrush Current
Power Factor
No Load Input Power
Earth Leakage Current
Input Protection
⢠85-264 VAC
⢠47-63 Hz
⢠0.85 A max at 115 VAC
⢠65 A max at 230 VAC
⢠EN61000-3-2, Class A
⢠<0.3 W
⢠<250 µA at 264 VAC, 60 Hz
⢠Internal T2 A/250 V fuse in line and neutral
Output
Output Voltage
⢠See table
Initial Set Accuracy
⢠Single output: ±1% at 60% load,
Multiple output: ±1% on V1, ±5% on V2
& V3 at 60% load
Minimum Load
⢠10% minimum load required on V1 & V2
of multi output versions
Start Up Delay
⢠1.3 s max
Start Up Rise Time
⢠15 ms typical
Hold Up Time
⢠10 ms min at full load at 115 VAC
Line Regulation
⢠±0.5% max
Load Regulation
⢠V1 & V3: ±2%, V2: ±4% (see note 3)
Cross Regulation
⢠V2: 5%, 10-100% load change on V1
(see note 4)
Transient Response
⢠4% max deviation, recovering to less than
1% within 500 µs for 50% step load
change at 1 A/µs
Ripple & Noise
⢠1% pk-pk, measured with 20 MHz
bandwidth
Overvoltage Protection ⢠110-140% of nominal output voltage
on V1 only, recycle input to reset
Overload Protection
⢠Single output: 140-160% of nominal power
Multiple output: 120-150% of nominal power
on V1 and V2 only
Short Circuit Protection ⢠Trip and restart (hiccup mode)
Temperature
Coefficient
⢠±0.02%/°C max
General
Efficiency
Isolation
Switching Frequency
MTBF
⢠See tables
⢠4000 VAC Input to Output
1500 VAC Input to Ground
500 VAC Output to Ground
⢠40-130 kHz variable
⢠>400 kHrs to MIL-HDBK-217F
at 25 °C, GB
Environmental
Operating Temperature ⢠-10 °C to +70 °C, derate from 100% load
at 50 °C to 50% load at 70 °C
Cooling
⢠Natural convection
Operating Humidity ⢠5% to 95% RH, non condensing
Storage Temperature ⢠-40 °C to +85 °C
Shock
⢠30 g pk, half sine, 6 axes
Vibration
⢠2 g rms, 5 Hz to 500 Hz, 3 axes
EMC & Safety
Emissions
Harmonic Currents
Voltage Flicker
ESD Immunity
Radiated Immunity
EFT / Burst
Surge
Conducted Immunity
Dips & Interruptions
Safety Approvals
⢠EN55022, level B conducted & radiated
⢠EN61000-3-2, class A
⢠EN61000-3-3
⢠EN61000-4-2, ±4 kV indirect contact,
Perf Criteria A
⢠EN61000-4-3, level 2, Perf Criteria A
⢠EN61000-4-4, level 3 Perf Criteria A
⢠EN61000-4-5, installation class 3,
Perf Criteria A
⢠EN61000-4-6, level 3, Perf Criteria A
⢠EN61000-4-11, 30% 10 ms, 60% 100 ms,
100% 5000 ms, Perf Criteria A, B, B
⢠EN60950-1, cUL60950, IEC60950-1,
EN60601-1, cUL60601-1, IEC60601-1
|
▷ |