ECP20US03 Datasheet, PDF (1/2 Pages) XP Power Limited – PCB Mount | |||
|
20 Watts
ECP20 Series
xppower.com
⢠Low Profile, 0.73â
⢠Class II Construction
⢠PCB Mounting
⢠Single Outputs from 3.3 to 48 V
⢠Dual Outputs from 12 to 24 V
⢠<0.3 W No Load Input Power
⢠Peak Load Capability
Specification
Input
Input Voltage
Input Frequency
Input Current
Inrush Current
Power Factor
No Load Input Power
⢠85-264 VAC
⢠47-63 Hz
⢠0.5 A max at 115 VAC
⢠40 A max at 230 VAC
⢠Conforms to EN61000-3-2, Class A
⢠<0.3 W
Output
Output Voltage
⢠See table
Initial Set Accuracy ⢠±1% at 60% load
Minimum Load
⢠No minimum load required
Start Up Delay
⢠1.3 s max
Start Up Rise Time
⢠15 ms typical
Hold Up Time
⢠10 ms min at full load & 115 VAC
Line Regulation
⢠±0.5% max
Load Regulation
⢠±1.0% max
Transient Response
⢠4% max deviation, recovering to less than
1% within 500us for 50% step load
change at 1 A/µs
Ripple & Noise
⢠3.3 & 5 V versions: 50 mV, 1% for others
measured with 20 MHz BW
Overvoltage Protection ⢠110-140% of nominal output voltage
Overload Protection ⢠150-180% of full load current
Short Circuit Protection ⢠Trip and restart (Hiccup mode)
Temperature
Coefficient
⢠0.02%/°C max
General
Efficiency
Isolation
Switching Frequency
⢠See tables
⢠3000 VAC Input to Output
⢠65 kHz typical
Environmental
Operating Temperature ⢠0 °C to +70 °C, derate from 100% load at
50 °C to 50% load at 70 °C
Cooling
⢠Natural convection
Operating Humidity ⢠5% to 95% RH, non condensing
Storage Temperature ⢠-40 °C to +85 °C
Shock
⢠30g, half sine, 6 axis
Vibration
⢠5-50 Hz, 2g 15 mins/sweep, 30 mins for
each of 3 axes
EMC & Safety
Emissions
Harmonic Currents
Voltage Flicker
ESD Immunity
Radiated Immunity
EFT / Burst
Surge
Conducted Immunity
Dips & Interruptions
Safety Approvals
⢠EN55022, level B conducted & radiated
⢠EN61000-3-2, class A
⢠EN61000-3-3
⢠EN61000-4-2, ±4 kV indirect contact,
Perf Criteria A
⢠EN61000-4-3, 3 V/m, Perf Criteria A
⢠EN61000-4-4, level 2 Perf Criteria A
⢠EN61000-4-5, level 2 Perf Criteria A
⢠EN61000-4-6, 3 V Perf Criteria A
⢠EN61000-4-11, 70% UT 10ms, 40% UT
100ms, <5% UT 5000ms,
Perf Criteria A, B, B
⢠EN60950, cUL60950, IEC60950-1
|
▷ |