English
Language : 

ECP130 Datasheet, PDF (1/6 Pages) XP Power Limited – AC-DC Power Supplies
ECP130 Series
130 Watts
• 100 W Convection/130 W Forced-cooled Ratings
• 2” by 3” Footprint
• Low 1.1” Profile
• High Efficiency, up to 95%
• Medical and ITE Approvals
• High Power Density
• Less than 0.5 W No Load Input Power
• 3 Year Warranty
AC-DC Power Supplies
The ECP130 series is designed to minimize the no load power consumption and maximize efficiency
to facilitate equipment design to meet the latest environmental legislation. Approved for medical and
ITE applications, this range of single output AC-DC power supplies are packaged in a low profile 1.1”
height with a foot print of just 2” by 3”. The ECP130 provides up to 130 W force-cooled or 100 W
convection-cooled leading to very high power densities of 19.7 W/in3 or 15.1 W/in3 respectively. The
power supply contains two fuses and low leakage currents as required by medical applications and
is safety approved to operate in a 80 °C ambient. The low profile and safety approvals covering ITE
and medical standards along with conducted emissions to EN55011/22 level B allow the versatile
ECP130 series to be used in a vast range of applications.
Dimensions:
ECP130:
3.00 x 2.00 x 1.10” (76.2 x 50.8 x 28.0 mm)
Models & Ratings
Output
Power
130 W
130 W
130 W
130 W
130 W
130 W
130 W
Output
Voltage
12.0 V
15.0 V
18.0 V
24.0 V
28.0 V
36.0 V
48.0 V
Output Current
Convection-cooled
Forced-cooled(1)
8.33 A
10.83 A
6.66 A
8.66 A
5.55 A
7.22 A
4.16 A
5.41 A
3.57 A
4.64 A
2.77 A
3.61 A
2.08 A
2.70 A
Notes
1. Requires 10 CFM.
2. Typical efficiency measured at full load and 230VAC input.
3. Add suffix ‘-S’ for input and output screw terminals e.g. ECP130PS24-S
Efficiency(2)
93%
93%
93%
93%
93%
93%
93%
Model Number(3)
ECP130PS12
ECP130PS15
ECP130PS18
ECP130PS24
ECP130PS28
ECP130PS36
ECP130PS48
Summary
Characteristic
Input Range
No Load Input Power
Efficiency
Operating Temperature
Safety Approvals
ITE
Medical
Minimum
Typical
Maximum
Units
Notes & Conditions
85
115/230
264
VAC
Derate load from 100% at 90 VAC to 85% at 85 VAC
0.5
W
95
%
230 VAC (see fig.1 & 2)
-30
+80
°C
See derating curve (fig.3)
IEC60950, UL60950-1, CSA 22.2 No.60950-1-11 Ed 2, EN60950-1, LVD
IEC60601-1 Ed 3.1 Including Risk Management, ANSI/AAMI ES60601-1 & CSA C22.2 No.6061-1:08, EN60601-1
1
www.xppower.com