ECP Datasheet, PDF (1/2 Pages) Hammond Manufacturing Ltd. – Systeme de commande Eclipse - NEMA 12 | |||
|
20 Watts
ECP Series
xppower.com
⢠Low Profile, 0.73â
⢠Class II Construction
⢠PCB Mounting
⢠Single Outputs from 3.3 to 48 V
⢠Dual Outputs from 12 to 24 V
⢠<0.3 W No Load Input Power
⢠3 Year Warranty
Specification
Input
Input Voltage
Input Frequency
Input Current
Inrush Current
Earth Leakage Current
Power Factor
No Load Input Power
Input Protection
⢠85-264 VAC (120-370 VDC)
⢠47-63 Hz
⢠0.5 A max at 115 VAC
⢠40 A max at 230 VAC, cold start 25 °C
⢠Class II construction, no earth
⢠Conforms to EN61000-3-2, Class A
⢠<0.3 W
⢠T1A / 250 VAC fuse in line
Output
Output Voltage
⢠See table
Initial Set Accuracy ⢠±1% at 60% load
Minimum Load
⢠10% on dual output models only
Start Up Delay
⢠1.3 s max
Start Up Rise Time
⢠15 ms typical
Hold Up Time
⢠10 ms min at full load & 115 VAC
Line Regulation
⢠±0.5% max
Load Regulation
⢠±1.0% max (single output models)
±2.0% max (dual output models)
Cross Regulation
⢠Dual output models: 3% on one
output when the other is varied from
10%-100% load
Transient Response
⢠4% max deviation, recovering to less than
1% within 500µs for 50% step load
change at 1 A/µs
Ripple & Noise
⢠3.3 & 5 V versions: 50 mV, 1% for others
measured with 20 MHz bandwidth
Overvoltage Protection ⢠110-140% of nominal output voltage
Overload Protection ⢠150-180% of full load current
Short Circuit Protection ⢠Trip and restart (hiccup mode)
Peak Load
⢠See table
Temperature
Coefficient
⢠±0.02%/°C max
General
Efficiency
Isolation
Switching Frequency
Power Density
MTBF
⢠See tables
⢠3000 VAC Input to Output
⢠100 kHz typical
⢠6.80 W/in3
⢠>400 kHrs to MIL-HDBK-217F
at 25 °C, GB
Environmental
Operating Temperature ⢠-10 °C to +70 °C, derate from 100% load
at 50 °C to 50% load at 70 °C
Cooling
⢠Natural convection
Operating Humidity ⢠5% to 90% RH, non-condensing
Storage Temperature ⢠-40 °C to +90 °C
Shock
⢠30 g, half sine, 6 axes
Vibration
⢠5 to 50 Hz, accelerated 7.35 m/s
each x, y, z axes
Altitude
⢠3000 m
EMC & Safety
Emissions
Harmonic Currents
Voltage Flicker
ESD Immunity
Radiated Immunity
EFT / Burst
Surge
Conducted Immunity
Magnetic Field
Dips & Interruptions
Safety Approvals
⢠EN55022, level B conducted & radiated
⢠EN61000-3-2, class A
⢠EN61000-3-3
⢠EN61000-4-2, ±4 kV coupling plate
discharge, Perf Criteria A
⢠EN61000-4-3, level 2, Perf Criteria A
⢠EN61000-4-4, level 2 Perf Criteria A
⢠EN61000-4-5, installation class 3,
Perf Criteria A
⢠EN61000-4-6, level 2, Perf Criteria A
⢠EN61000-4-8, 1 A/m, Perf Criteria A
⢠EN61000-4-11, 30% 10 ms, 60% 100 ms,
100% 5000 ms, Perf Criteria A, B, B
⢠EN60950-1, cUL60950, IEC60950-1
|
▷ |