20 Watts
ECP Series
xppower.com
• Low Profile, 0.73”
• Class II Construction
• PCB Mounting
• Single Outputs from 3.3 to 48 V
• Dual Outputs from 12 to 24 V
• <0.3 W No Load Input Power
• 3 Year Warranty
Specification
Input
Input Voltage
Input Frequency
Input Current
Inrush Current
Earth Leakage Current
Power Factor
No Load Input Power
Input Protection
• 85-264 VAC (120-370 VDC)
• 47-63 Hz
• 0.5 A max at 115 VAC
• 40 A max at 230 VAC, cold start 25 °C
• Class II construction, no earth
• Conforms to EN61000-3-2, Class A
• <0.3 W
• T1A / 250 VAC fuse in line
Output
Output Voltage
• See table
Initial Set Accuracy • ±1% at 60% load
Minimum Load
• 10% on dual output models only
Start Up Delay
• 1.3 s max
Start Up Rise Time
• 15 ms typical
Hold Up Time
• 10 ms min at full load & 115 VAC
Line Regulation
• ±0.5% max
Load Regulation
• ±1.0% max (single output models)
±2.0% max (dual output models)
Cross Regulation
• Dual output models: 3% on one
output when the other is varied from
10%-100% load
Transient Response
• 4% max deviation, recovering to less than
1% within 500µs for 50% step load
change at 1 A/µs
Ripple & Noise
• 3.3 & 5 V versions: 50 mV, 1% for others
measured with 20 MHz bandwidth
Overvoltage Protection • 110-140% of nominal output voltage
Overload Protection • 150-180% of full load current
Short Circuit Protection • Trip and restart (hiccup mode)
Peak Load
• See table
Temperature
Coefficient
• ±0.02%/°C max
General
Efficiency
Isolation
Switching Frequency
Power Density
MTBF
• See tables
• 3000 VAC Input to Output
• 100 kHz typical
• 6.80 W/in3
• >400 kHrs to MIL-HDBK-217F
at 25 °C, GB
Environmental
Operating Temperature • -10 °C to +70 °C, derate from 100% load
at 50 °C to 50% load at 70 °C
Cooling
• Natural convection
Operating Humidity • 5% to 90% RH, non-condensing
Storage Temperature • -40 °C to +90 °C
Shock
• 30 g, half sine, 6 axes
Vibration
• 5 to 50 Hz, accelerated 7.35 m/s
each x, y, z axes
Altitude
• 3000 m
EMC & Safety
Emissions
Harmonic Currents
Voltage Flicker
ESD Immunity
Radiated Immunity
EFT / Burst
Surge
Conducted Immunity
Magnetic Field
Dips & Interruptions
Safety Approvals
• EN55022, level B conducted & radiated
• EN61000-3-2, class A
• EN61000-3-3
• EN61000-4-2, ±4 kV coupling plate
discharge, Perf Criteria A
• EN61000-4-3, level 2, Perf Criteria A
• EN61000-4-4, level 2 Perf Criteria A
• EN61000-4-5, installation class 3,
Perf Criteria A
• EN61000-4-6, level 2, Perf Criteria A
• EN61000-4-8, 1 A/m, Perf Criteria A
• EN61000-4-11, 30% 10 ms, 60% 100 ms,
100% 5000 ms, Perf Criteria A, B, B
• EN60950-1, cUL60950, IEC60950-1