ECM40US05 Datasheet, PDF (1/4 Pages) XP Power Limited – AC-DC Power Supplies | |||
|
40-100 Watts
ECM Series
xppower.com
⢠Compact Size - High Power Density
⢠Industrial & Medical Approvals
⢠Low Leakage Current
⢠Level B Conducted Emissions
⢠EN61000-3-2, -3 Compliant
⢠Convection-cooled
⢠Class II Approved 40-60 W Models
Specification
Input
Input Voltage
⢠90-264 VAC (120-370 VDC)
Input Frequency
⢠47-63 Hz; 440 Hz
Input Current
⢠40 W: 0.4 A max at 230 VAC
60 W: 0.6 A max at 230 VAC
100 W: 0.9 A max at 230 VAC
Inrush Current
⢠40 A max at 230 VAC
Earth Leakage Current ⢠<125 µA at 115 VAC/60 Hz
<210 µA at 230 VAC/50 Hz
Input Protection
⢠Internal 3.15 A fuse in line and neutral
Output
Output Voltage
⢠See tables
Output Voltage Trim
⢠±5% on 3.3 V & 5 V versions, ±10% on
other single output models and V1 of
multi-output models. See note 1 for
ECM40/60 models
Initial Set Accuracy ⢠±1.0% V1, ±5% V2, V3 & V4
Minimum Load
⢠See tables
Start Up Delay
⢠2 s max
Start Up Rise Time
⢠50 ms
Hold Up Time
⢠16/75 ms min at 115/230 VAC
Line Regulation
⢠±0.5%
Load Regulation
⢠±1% single output models;
±3% V1, ±5% V2 & V3 ECM40/60
multi-output models.
±1% V1 & V2, ±5% V3 & V4 ECM100
Cross Regulation
⢠2% on ECM40/60 only
Over/Undershoot
⢠None at turn on/off
Transient Response
⢠4% max. deviation, recovery to within
1% in 500 µs for a 25% load change
Ripple & Noise
⢠1% pk-pk, 20 MHz bandwidth
Overvoltage Protection ⢠115-135% Vnom, recycle input to reset
Overload Protection
⢠110-150% on primary power limit,
auto recovery
Short Circuit Protection ⢠Trip and restart (Hiccup mode)
Temperature
Coefficient
⢠0.05%/°C
General
Efficiency
Isolation
Switching Frequency
Power Density
MTBF
⢠80-85% depending on model
⢠4000 VAC Input to Output
1500 VAC Input to Ground
500 VAC Output to Ground
⢠70 kHz typical
⢠60 W: 6.25 W/In3
100 W: 7.40 W/In3
⢠250 kHrs per MIL-HDBK-217F
Environmental
Operating Temperature ⢠0 °C to +70 °C. Refer to derating curves
for specific operating limitations.
Cooling
⢠Convection & fan-cooled ratings
(see derating curves)
Operating Humidity ⢠95% RH, non-condensing
Storage Temperature ⢠-20 °C to +85 °C
Operating Altitude
⢠3000 m
Shock
⢠30 g pk, half sine, 6 axes
Vibration
⢠2 g rms, 5 Hz to 500 kHz, 3 axes
EMC & Safety
Emissions
Harmonic Currents
Voltage Flicker
ESD Immunity
Radiated Immunity
EFT/Burst
Surge
Conducted Immunity
Dips & Interruptions
Safety Approvals
⢠EN60601-1-2, EN61204-3, FCC 20780,
EN55022 & EN55011, level B conducted
⢠EN61000-3-2
⢠EN61000-3-3
⢠EN61000-4-2, level 2 Perf Criteria A
⢠EN61000-4-3, 10 V/m Perf Criteria A
⢠EN61000-4-4, level 3 Perf Criteria A
⢠EN61000-4-5, level 3 Perf Criteria A
⢠EN61000-4-6, 10 V Perf Criteria A
⢠EN61000-4-11, 30% 10 ms,
60% 100 ms, 100% 5000 ms
Perf Criteria A, B, B
⢠EN60950, UL60950, CSA 22.2 601.1,
EN60601-1, UL60601-1,
CCC pending, contact sales
|
▷ |