ECL15US03 Datasheet, PDF (1/2 Pages) XP Power Limited – PCB Mount | |||
|
15 Watts
ECL15 Series
xppower.com
⢠Ultra Compact Size
⢠Low Cost
⢠Single Outputs from 3.3 to 48 V
⢠PCB Mount & Open Frame
⢠Encapsulated PCB Mount
⢠Class II
⢠Peak Load Capability
Specification
Input
Input Voltage
⢠85-264 VAC (120-370 VDC)
Input Frequency
⢠47-63 Hz
Input Current
⢠0.3 A rms at 230 VAC
Inrush Current
⢠20 A at 115 VAC, 40 A at 230 VAC,
Earth Leakage Current ⢠Class II construction no earth
Input Protection
⢠Internal 2 A fuse
Output
Output Voltage
⢠See tables
Output Voltage Trim ⢠±5% (not encapsulated units)
Initial Set Accuracy ⢠±1%
Minimum Load
⢠No minimum load required
Start Up Delay
⢠2 s max
Start Up Rise Time
⢠14 ms max
Hold Up Time
⢠16 ms typical at full load & 115 VAC
Line Regulation
⢠±0.5% max
Load Regulation
⢠±1% max
Transient Response
⢠4% max deviation, recovery to within
1% in 500 µs for a 25% load change
Ripple & Noise
⢠3.3-5 V versions: 50 mV pk-pk,
12-15 V versions: 120 mV pk-pk,
24-48 V versions: 200 mV pk-pk,
20 MHz BW
Overvoltage Protection ⢠115-135% Vnom, recycle input to reset
Overload Protection ⢠120-150%
Short Circuit Protection ⢠Trip and restart (Hiccup mode)
Temperature
Coefficient
⢠0.05%/°C
General
Efficiency
Isolation
Switching Frequency
Power Density
MTBF
⢠See tables
⢠3000 VAC Input to Output
⢠70 kHz typical
⢠4.8 W/In3 (PCB Mount version)
⢠>400 kHrs per MIL-HDBK-217F
Environmental
Operating Temperature ⢠-20 °C to +70 °C, derate linearly from
100% at +50 °C to 50% at +70 °C
Cooling
⢠Convection-cooled
Operating Humidity ⢠95% RH, non-condensing
Storage Temperature ⢠-40 °C to +85 °C
Operating Altitude
⢠3000 m
Vibration
⢠2 g, 10 Hz to 500 kHz, 10 mins/cycle,
60 mins each cycle
EMC & Safety
Emissions
Harmonic Currents
ESD Immunity
Radiated Immunity
EFT/Burst
Surge
Conducted Immunity
Magnetic Fields
Dips & Interruptions
Safety Approvals
⢠EN55022, level B conducted & radiated
⢠EN61000-3-2, EN61000-3-3
⢠EN61000-4-2, level 3 Perf Criteria A
⢠EN61000-4-3, 10 V/m 80% mod
Perf Criteria A
⢠EN61000-4-4, level 3 Perf Criteria A
⢠EN61000-4-5, level 3 Perf Criteria A
⢠EN61000-4-6, 10 Vrms Perf Criteria A
⢠EN61000-4-8, 10 A/m Perf Criteria A
⢠EN61000-4-11, 70% UT for 10 ms,
40% UT for 100 ms, <5% UT for 5000 ms
Perf Criteria A, B, B
⢠EN60950, UL60950,
CSA22.2 No. 234 per cUL
|
▷ |