English
Language : 

ECL10US03 Datasheet, PDF (1/2 Pages) XP Power Limited – AC-DC Power Supplies
10 Watts
ECL10 Series
xppower.com
• Ultra Compact Size
• Low Cost
• Single Outputs from 3.3 to 48 V
• PCB Mount & Open Frame
• Encapsulated PCB Mount
• Class II
• Peak Load Capability
Specification
Input
Input Voltage
• 85-264 VAC (120-370 VDC)
Input Frequency
• 47-63 Hz
Input Current
• 0.20 A rms at 230 VAC
Inrush Current
• 20 A at 115 VAC, 40 A at 230 VAC,
Earth Leakage Current • Class II construction no earth
Input Protection
• Internal 1 A fuse
Output
Output Voltage
• See tables
Output Voltage Trim • ±5% (not encapsulated units)
Initial Set Accuracy • ±1%
Minimum Load
• No minimum load required
Start Up Delay
• 2 s max
Start Up Rise Time
• 14 ms max
Hold Up Time
• 16 ms typical at full load &115 VAC
Line Regulation
• ±0.5% max
Load Regulation
• ±1% max
Transient Response
• 4% max deviation, recovery to within
1% in 500 µs for a 25% load change
Ripple & Noise
• 3.3-5 V versions: 50 mV pk-pk,
12-15 V versions: 120 mV pk-pk,
24-48 V versions: 200 mV pk-pk,
20 MHz BW
Overvoltage Protection • 115-135% Vnom, recycle input to reset
Overload Protection • 120-150%
Short Circuit Protection • Trip and restart (Hiccup mode)
Temperature
Coefficient
• 0.05%/°C
General
Efficiency
Isolation
Switching Frequency
Power Density
MTBF
• See tables
• 3000 VAC Input to Output
• 70 kHz typical
• 5.5 W/In3 (PCB mount version)
• >450 kHrs per MIL-HDBK-217F
Environmental
Operating Temperature • -20 °C to +70 °C, derate linearly from
100% at +50 °C to 50% at +70 °C
Cooling
• Convection-cooled
Operating Humidity • 95% RH, non-condensing
Storage Temperature • -40 °C to +85 °C
Operating Altitude
• 3000 m
Vibration
• 2 g, 10 Hz to 500 kHz, 10 mins/cycle,
60 mins each cycle
EMC & Safety
Emissions
Harmonic Currents
ESD Immunity
Radiated Immunity
EFT/Burst
Surge
Conducted Immunity
Magnetic Fields
Dips & Interruptions
Safety Approvals
• EN55022, level B conducted & radiated
• EN61000-3-2, EN61000-3-3
• EN61000-4-2, level 3 Perf Criteria A
• EN61000-4-3, 10 V/m 80% mod
Perf Criteria A
• EN61000-4-4, level 3 Perf Criteria A
• EN61000-4-5, level 3 Perf Criteria A
• EN61000-4-6, 10 Vrms Perf Criteria A
• EN61000-4-8, 10 A/m Perf Criteria A
• EN61000-4-11, 70% UT for 10 ms,
40% UT for 100 ms, <5% UT for 5000 ms
Perf Criteria A, B, B
• EN60950, UL60950,
CSA22.2 No. 234 per cUL