English
Language : 

ECE80 Datasheet, PDF (1/3 Pages) XP Power Limited – AC-DC Power Supplies
ECE80 Series
AC-DC Power Supplies
80 Watts
• Ultra Compact Size
• Single Outputs from 12 to 48 V
• Encapsulated
• PCB, Chassis Mount and DIN Rail Versions
• <0.3 W No Load Input Power
• -40 to +70 °C Operation
• Peak Load Capability
• 3 Year Warranty
The ECE80 series of compact encapsulated AC-DC power modules are available in both PCB &
chassis mount versions offering exceptional power density of >11W/in3. Output voltages are
available from 12 – 48 VDC and these “green power” modules offer high active mode efficiency and
low no load power consumption. They also provide a peak load capability up to 130% of nominal
power for up to 30s and a wide operating temperature range from -40 to +70°C.
Dimensions:
ECE80:
3.60 x 1.80 x 1.10” (91.4 x 45.72 x 28.0 mm)
ECE80-S:
4.45 x 1.87 x 1.12” (113.0 x 47.5 x 28.5 mm)
Models & Ratings
Output Power
80 W
80 W
80 W
80 W
80 W
Output Voltage
12.0 V
15.0 V
24.0 V
36.0 V
48.0 V
Output Current
Nominal
Peak (1)
6.67 A
8.67 A
5.33 A
6.93 A
3.33 A
4.33 A
2.22 A
2.89 A
1.67 A
2.17 A
Efficiency (4)
88%
88%
87%
87%
87%
Model Number (2,3)
ECE80US12
ECE80US15
ECE80US24
ECE80US36
ECE80US48
Notes
1. Peak load lasting <30 s with a maximum duty cycle of 10%, average output power not to exceed nominal power.
2. Add suffix -S to model number to denote chassis mount with screw terminal type, e.g. ECE80US12-S.
3. A screw terminal version (-S) is available with DIN Clip attached. Add suffix ‘D’, e.g. ECE80US24-SD. DIN Rail mounting clip is available as a separate item, order
code ECE80 DIN CLIP.
4. Average of efficiencies measured at 25%, 50%, 75% & 100% load with 230 VAC input.
Summary
Characteristic
Input Range
No Load Input Power
Efficiency
Operating Temperature
EMC
Safety Approvals
Minimum
85
86
Typical
87
Maximum
264
<0.3
<0.5
88
Units
VAC
W
W
%
Notes & Conditions
Derate load from 100% at 90 VAC to 90% at 85 VAC
12-36 V versions
48 V version
See note 4 above
Some specification parameters may not met below -25 °C.
-40
+70
°C
Derate linearly from 100% load at +50 °C to 50% load at
70 °C.
EN55022 & 32 Level B Conducted & Radiated, EN61000-4, EN61000-3
EN60950-1, UL60950-1, CSA22.2 No. 234 per cUL
1