ECE05US03 Datasheet, PDF (1/2 Pages) XP Power Limited – 5/10 Watts ECE Series | |||
|
5/10 Watts
ECE Series
xppower.com
⢠Ultra Compact Size
⢠Single Outputs from 3.3 to 48 V
⢠Encapsulated PCB Mount
⢠<0.3 W No Load Input Power
⢠Peak Load Capability
⢠No External Components Required
⢠3 Year Warranty
Specification
Input
Input Voltage
Input Frequency
Input Current
Inrush Current
Power Factor
Earth Leakage Current
No Load Input Power
Input Protection
⢠85-264 VAC (120-370 VDC) derate load
from 100% at 90 VAC to 90% at 85 VAC
⢠47-63 Hz
⢠ECE05: 0.1 A rms at 230 VAC
ECE10: 0.2 A rms at 230 VAC
⢠20 A at 115 VAC, 40 A at 230 VAC,
cold start at 25 °C
⢠EN61000-3-2 Class A
⢠Class II construction no earth
⢠<0.3 W
⢠Internal T1 A/250 VAC fuse
Output
Output Voltage
⢠See tables
Initial Set Accuracy ⢠±1%
Minimum Load
⢠No minimum load required
Start Up Delay
⢠2 s max
Start Up Rise Time
⢠25 ms max
Hold Up Time
Line Regulation
⢠8 ms/40 ms typical at full load and
115/230 VAC
⢠±0.5% max
Load Regulation
⢠±1% max
Transient Response
⢠4% max deviation, recovery to within
1% in 500 µs for a 25% load change
Ripple & Noise
⢠3.3-5 V versions: 60 mV pk-pk, all other
models 1% pk-pk max 20 MHz bandwidth
Overvoltage Protection ⢠125-190%, 195-216% ECE10US03
Overload Protection ⢠125-190%
Short Circuit Protection ⢠Trip and restart (hiccup mode)
Temperature
Coefficient
⢠0.05%/°C
General
Efficiency
Isolation
Switching Frequency
Power Density
MTBF
⢠See tables
⢠4000 VAC Input to Output
⢠130 kHz typical
⢠ECE05: 8.3 W/In3
ECE10: 11.1 W/In3
⢠>450 kHrs to MIL-HDBK-217F at 25 °C, GB
Environmental
Operating Temperature ⢠-25 °C to +70 °C, derate linearly from
100% at +50 °C to 50% at +70 °C
Cooling
⢠Convection-cooled
Operating Humidity ⢠95% RH, non-condensing
Storage Temperature ⢠-40 °C to +85 °C
Operating Altitude
⢠3048 m, 10,000 ft
Vibration
⢠2 g, 10 Hz to 500 Hz, 10 mins/cycle,
60 mins each cycle
EMC & Safety
Emissions
Harmonic Currents
ESD Immunity
Radiated Immunity
EFT/Burst
Surge
Conducted Immunity
Magnetic Fields
Dips & Interruptions
Safety Approvals
⢠EN55022, level B conducted & radiated*
⢠EN61000-3-2, EN61000-3-3
⢠EN61000-4-2, level 3 Perf Criteria A
⢠EN61000-4-3, 10 V/m 80% mod
Perf Criteria A
⢠EN61000-4-4, level 3 Perf Criteria A
⢠EN61000-4-5, installation Class 3,
Perf Criteria A
⢠EN61000-4-6, 10 Vrms Perf Criteria A
⢠EN61000-4-8, 10 A/m Perf Criteria A
⢠EN61000-4-11, 30% for 10 ms,
60% for 100 ms, 100% for 5000 ms
Perf Criteria A, B, B
⢠EN60950-1, UL60950-1,
CSA22.2 No. 234 per cUL
Notes
* If output is connected to GND, please contact applications engineering for further information.
|
▷ |