DSL240 Datasheet, PDF (1/2 Pages) XP Power Limited – Ultra Slim Design
240 Watts
DSL240 Series
xppower.com
• Ultra Slim Design
• 150% Peak Load for 3 seconds
• Full Power from 40 °C to +60°C
• High Efficiency – Up to 93%
• Hazardous Locations Approval
• Parallel Capability
• 3 Year Warranty
Specification
Input
Input Voltage
Input Frequency
Input Current
Inrush Current
Power Factor
Earth Leakage Current
Input Protection
• 88-264 VAC (120-375 VDC)
• 47-63 Hz
• 2.3 A at 115 VAC, 1.15 A at 230 VAC
• 24/48 A max at 115/230 VAC
• 0.97 typical at 230 VAC
Conforms to EN61000-3-2 Class A.
• 3.5 mA maximum
• Internal fuse in line, T5.0 A/250 VAC
Output
Output Voltage
• See table
Output Voltage Trim • See table
Initial Set Accuracy • +1% at 100% load
Minimum Load
• No minimum load required
Start Up Delay
• 1.0 s max
Start Up Rise Time
• 150 ms max
Hold Up Time
• 25 ms minimum at full load and 115 VAC
Line Regulation
• ±1%
Load Regulation
• ±1% (±5% in parallel mode)
Transient Response
• 10% maximum deviation, recovering to
less than 1% within 2 ms for 50% step
load change at 0.2 A/µs
Ripple & Noise
• 100 mV pk-pk maximum, measured with
20 MHz bandwidth
Overvoltage Protection • 12 V output: 15-16.5 V,
24 V output: 30-33 V
Overload Protection
• 120-150% of rated current
(see application note)
Short Circuit Protection • Trip and restart (hiccup mode)
auto recovery within 7 s
Temperature
Coefficient
• ±0.03%/°C
Thermal Protection
• 110°C max, measured on internal heatsink
auto recovery
Parallel Operation
• A maximum of 3 units can be paralleled.
Max power available is 90% of total rated
power. Minimum load of 10% required per
unit
Maximum Capacitive • 7000 µF (start up delay increases to 1.5s
Load
and rise time to 500 ms)
General
Efficiency
Isolation
Switching Frequency
DC OK Signal
Output LED
MTBF
• See table
• 3000 VAC Input to Output
1500 VAC Input to Ground
500 VAC Output to Ground
• 100 kHz typical PFC & main converter at
230 VAC and full load
• Volt free contacts rated at 60 VDC/ 0.3 A
on 24 V versions only
• Green LED to indicate output on. Red LED
to indicate low output voltage. See
mechanical details for operating range.
• >370 kHrs to BELLCORE Issue 6 at 40 °C,
GB
Environmental
Operating Temperature • -40 °C to +70 °C (see derating curves)
Cooling
• Natural convection
Operating Humidity • 20-95% RH, non-condensing
Protection
• IP20
Storage Temperature • -40 °C to +85 °C
Operating Altitude
• 4850 m
Shock
• IEC68-2-27, 4 g, 22 ms half sine, 3 times
in each of 6 axes
Vibration
• IEC68-2-6, 10-500 Hz, 2 g 10 mins/sweep.
60 mins for each of 3 axes
EMC & Safety
Emissions
Harmonic Currents
Voltage Flicker
ESD Immunity
Radiated Immunity
EFT/Burst
Surge
Conducted Immunity
Magnetic Field
Dips & Interruptions
Safety Approvals
• EN55022, class B conducted & radiated
• EN61000-3-2, class A
• EN61000-3-3
• EN61000-4-2, 8 KV Contact,
15 KV Air Discharge, Perf Criteria A
• EN61000-4-3, 10 V/m Perf Criteria A
• EN61000-4-4, level 4 Perf Criteria A
• EN61000-4-5, Installation Class 4
Perf Criteria A
• EN61000-4-6, 10 V Perf Criteria A
• EN61000-4-8, level 4, Perf Criteria A
• EN55024, 30% 10 ms, 60% 100 ms,
100% 5000 ms Perf Criteria A, B, B
• UL508, UL60950-1, EN60950-1, ANSI/ISA
12.12.01 (Class I, Division 2, Groups A, B,
C and D)