DNR120-960TS Datasheet, PDF (1/2 Pages) XP Power Limited – Three Phase AC Input | |||
|
120 960 Watts
DNR120 960TS Series
xppower.com
⢠Three Phase AC Input
⢠Up to 93% Efficiency
⢠Wide Adjustment Range
⢠Full Power 40 º C to +60 º C
⢠Rugged Design for Industrial Applications
⢠Single Phase Input Operation (340 575 VAC)
⢠3 Year Warranty
Specification
Input
Input Voltage
Input Frequency
Input Current
Inrush Current
Power Factor
Earth Leakage Current
Input Protection
⢠340-575 VAC 3 phase (single phase
operation with 75% of rated output),
480-820 VDC
⢠47-63 Hz
⢠See tables
⢠DNR120: 10.0 A, DNR240: 20.0 A,
DNR480: 20.0 A, DNR960: 30.0 A,
typical at 480 VAC, cold start
⢠0.6 typical at 480 VAC input and nominal
load, DNR960TS: 0.8 typical at 480 VAC
input and nominal load
⢠0.32 mA
⢠3 internal fuses,
DNR120TS, DNR240TS: T2.0 A, 600 VAC,
DNR480TS: T3.15 A, 500 VAC,
DNR960TS: T5.0 A, 500 VAC
Output
Output Voltage
⢠See table
Output Voltage Trim ⢠See table
Initial Set Accuracy ⢠±1%
Minimum Load
⢠No minimum load required
Start Up Delay
⢠<1 s (may increase at low
temperature extremes)
Start Up Rise Time
⢠<150 ms
Hold Up Time
⢠20 ms min at 480 VAC,
DNR960TS: 15 ms min at 480 VAC
Line Regulation
⢠±1%
Load Regulation
⢠±1% max (±5% for units in parallel (not
DNR120TS))
Parallel Operation
⢠2 units can be connected in parallel
(not DNR120TS), total power available is
90% of the rated current of each unit,
minimum load per unit 10%, use Ishare
connection for DNR960TS. Redundancy
module DPM10 available for load currents
up to 10 A, contact sales
Transient Response
⢠4% max deviation recovering to within
1% in 2 ms for 50% load change
Ripple & Noise
⢠100 mV pk-pk 20 MHz bandwidth,
DNR960TS: 80 mV pk-pk 20 MHz
bandwidth, (may increase at low
temperature extremes)
Overvoltage Protection ⢠120-145%, auto recovery
Overload Protection
⢠110%-140%, constant current,
auto recovery
Temperature Coefficient ⢠±0.03%/°C
Short Circuit Protection ⢠Continuous trip and restart (hiccup mode)
(DNR480TS switchable hiccup mode or
power limited )
General
Efficiency
Isolation
Switching Frequency
Signals
MTBF
DIN Rail
⢠See table
⢠3000 VAC Input to Output, 1500 VAC
Input to Ground, 500 VAC Output to
Ground
⢠DNR120TS: 70 kHz typical,
DNR240TS: 25 kHz typical,
DNR480TS: 80 kHz typical,
DNR960TS: 52 kHz typical
⢠DC ON indicator LED Green,
DC LOW indicator LED Red
DC OK: normally open relay on 24 V models
⢠DNR120TS: 550 kHrs, 240TS: 500 kHrs
480TS: 420 kHrs, 960TS: 380 kHrs to
Bellcore Issue 6, at +40 °C, GB
⢠Compatible with TS35/7.5 or TS35/15
Environmental
Operating Temperature ⢠-40 °C to 70 °C (DNR480TS -30 °C),
derate linearly from 60 °C at 2.5%/°C
(3.5%/°C for DNR960TS), start up at
-35 °C (DNR480TS -20 °C)
see derating curves
Cooling
⢠Convection-cooled with 25 mm free space
all sides
Operating Humidity ⢠20-95% RH, non-condensing
Storage Temperature ⢠-40 °C to +85 °C
Shock
⢠15 g, 11 ms, 3 axis, 6 faces, 3 shocks/face
Vibration
⢠2 g, 10 Hz to 500 Hz, along X, Y & Z axis,
60 min/axis, mounted on rail
EMC & Safety
Emissions
Harmonic Currents
Voltage Flicker
ESD Immunity
Radiated Immunity
EFT/Burst
Surge
Conducted Immunity
Magnetic Field
Dips & Interruptions
Safety Approvals
⢠EN55022, Class B conducted & radiated
⢠EN61000-3-2, Class A
⢠EN61000-3-3
⢠EN61000-4-2, level 4 Perf Criteria A
⢠EN61000-4-3, level 3 Perf Criteria A
⢠EN61000-4-4, level 4 Perf Criteria A
⢠EN61000-4-5, installation class 4,
Perf Criteria A
⢠EN61000-4-6, level 3 perf criteria A
⢠EN61000-4-8, level 4 perf criteria A
⢠EN61000-4-11, 30% 500 ms,
60% 200 ms, >95% 5000 ms
Perf Criteria A, A, A
⢠EN60950-1 UL508 UL60950-1
Pollution Degree 2,
UL60950-1 Overvoltage Category II
UL508 Overvoltage Category III,
ANSI/ISA 12.12.01 Class 1, Division 2,
Groups A,B,C and D
|
▷ |