DNR05US05 Datasheet, PDF (1/4 Pages) XP Power Limited – AC-DC Power Supplies | |||
|
5-60 Watts
DNR05-60 Series
xppower.com
⢠Rugged Design for Industrial Applications
⢠Up to 89% Efficiency
⢠Wide Adjustment Range
⢠DC OK 24 V Models
⢠DC Standby Versions
⢠Connector Options
⢠Full Power to +60 ËC
Specification
Input
Input Voltage
⢠90-264 VAC, 120-370 VDC: DNR05/10/18
85-264 VAC, 90-375 VDC: DNR30/60
Input Frequency
⢠47-63 Hz
Inrush Current
⢠5-18 W: 10/18 A at 115/230 VAC
30 W: 20/40 A at 115/230 VAC
60 W: 30/60 A at 115/230 VAC
Power Factor
⢠Meets EN61000-3-2 for class A equipment
Earth Leakage Current ⢠0.8 mA max
Output
Output Voltage
⢠See tables
Output Voltage Trim ⢠See tables
Initial Set Accuracy ⢠±1%
Minimum Load
⢠No minimum load required
Start Up Delay
⢠<1000 ms
Start Up Rise Time
⢠<150 ms
Hold Up Time
⢠5 W: 30/130 ms at 115/230 VAC
10 W: 25/100 ms at 115/230 VAC
18 W: 20/75 ms at 115/230 VAC
30 W: 20/30 ms at 115/230 VAC
60 W: 20/30 ms at 115/230 VAC
Line Regulation
⢠5-18 W: ±1.0% max
30-60 W: ±0.5% max
Load Regulation
⢠5-18 W: ±2.0% max
30-60 W: ±0.5% max
Transient Response ⢠300 µs for a 50% load change
Ripple & Noise
⢠50 mV pk-pk, 20 MHz BW
Overvoltage Protection ⢠Output clamps at 120-145% Vnom
Overload Protection ⢠105-145%
Short Circuit Protection ⢠5-18 W: Trip and restart (Hiccup mode)
30-60 W: Constant power
Temperature
Coefficient
⢠±0.03%/ºC
General
Efficiency
Isolation
Switching Frequency
Signals
MTBF
⢠See tables
⢠3000 VAC Input to Output
1500 VAC Input to Ground
500 VAC Output to Ground
⢠100 KHz typical
⢠DC ON indicator LED Green: All models
DC LOW indicator LED Red:
5-18 W models
DC OK: 24 V 30-60 W models
⢠200 kHrs typical per MIL-HDBK-217F
GF, +40 ºC
Environmental
Operating Temperature ⢠-10 °C to +70 °C, derate linearly from
+50 °C for 5 & 18 W models, +60 °C for
all other models (See derating curves)
Cooling
⢠Convection-cooled
Operating Humidity ⢠20-95% RH, non-condensing
Storage Temperature ⢠-25 ºC to +85 ºC
Shock
⢠4 g, 22 ms, X, Y & Z axis
Vibration
⢠1 g, 10 Hz to 500 kHz, along X, Y & Z axis
EMC & Safety
Emissions
Harmonic Currents
Voltage Flicker
ESD Immunity
Radiated Immunity
EFT/Burst
Surge
Dips & Interruptions
Safety Approvals
⢠EN55022, level B conducted
⢠EN61000-3-2, class A
⢠EN61000-3-3 amendments 1 & 2
⢠EN61000-4-2, level 3 Perf Criteria A
⢠EN61000-4-3, level 3 Perf Criteria A
⢠EN61000-4-4, level 3 Perf Criteria A
⢠EN61000-4-5, level 3 Perf Criteria A
⢠EN61000-4-11, 30% 10 ms,
60% 100 ms, 100% 5000 ms
Perf Criteria A, B, B
⢠EN60950-1:2001, UL508,
UL1310 - see note 3 & ratings table,
UL60950-1, cUL60950-1, CE Mark
|
▷ |