English
Language : 

DLG100PS12 Datasheet, PDF (1/2 Pages) XP Power Limited – 50150 Watts DLG Series
50 150 Watts
DLG Series
xppower.com
• AC Input LED Driver
• Constant Voltage & Current Operation
• High Power Factor
• High Efficiency
• Water Proof to IP67
• 90 305 VAC Input Voltage Range
• 3 Year Warranty
Specification
Input
Input Voltage
Input Frequency
Input Current
Inrush Current
Power Factor
Earth Leakage Current
No Load Input Power
Input Protection
• 90-305 VAC, see derating curve
• 47-63 Hz
• 50 W: 1.0 A at 115 VAC, 0.5 A at 230 VAC,
75 W: 1.2 A at 115 VAC, 0.6 A at 230 VAC,
100 W: 1.4 A at 115 VAC, 0.7 A at 230 VAC,
150 W: 2.0 A at 115 VAC, 1.0 A at 230 VAC
• 65 A at 230 VAC, cold start +25 °C
• >0.94 at 230 VAC, full load
• DLG50/75: 500 µA max at 230 VAC
DLG100/150: 750 µA max at 230 VAC
• 0.6 W max at 230 VAC
• DLG50/75 T2.5A/300V fuse fitted in line,
DLG100 T3.15A/300V fuse fitted in line,
DLG150 T4A/300V fuse fitted in line
Output
Output Voltage
• See table
Minimum Load
• No minimum load required
Start Up Delay
• 1.5 s max at 115 VAC
Hold Up Time
• DLG50/75: No hold up
DLG100/150: 16 ms minimum
Line Regulation
• ±0.5%
Load Regulation
• ±1.0% in constant voltage mode,
±5.0% in constant current mode
Turn On Overshoot
• 5% max
Transient Response
• 5% maximum deviation, recovery to within
1% in 10 ms for a 50% load change
Ripple & Noise
• DLG50/75(1)
DLG100/150: 150 mV pk-pk up to 36 V
output, 200 mV for 48 V output, 240 mV
for ≥54 V output (see note 2)
Overvoltage Protection • 110-142%, recycle mains to reset, only on
DLG100 & DLG150 versions
Overtemperature
Protection
• Unit shuts down, recycle mains to reset
Overload Protection • 105% maximum, auto recovery
Short Circuit Protection • Trip and restart (hiccup mode)
Temperature
Coefficient
• 0.04%/°C
Notes
1. DLG50/75 use a topology which results in increased levels of mains frequency
related ripple. Contact technical sales for details.
General
Efficiency
Isolation
Switching Frequency
MTBF
• See table
• 3750 VAC Input to Output
1880 VAC Input to Ground
500 VAC Output to Ground
• DLG50/75: 40-80 kHz
DLG100/150: PWM 60-80 kHz,
PFC 55-133 kHz
• >200 kHrs to MIL-HDBK-217F at 25 °C, GB
Environmental
Operating Temperature • DLG50/75: -40 °C to +60 °C
(see derating curve),
DLG100/150: -30 °C to +70 °C
(see derating curve)
Operating Humidity • 5-100% RH, non-condensing
Storage Temperature • -40 °C to +80 °C
Operating Altitude
• 3000 m
Vibration
• 10-500 Hz, 2 g, 10 mins/cycle, 6 cycles in
each of 3 axes
EMC & Safety
Emissions
Harmonic Currents
Voltage Flicker
ESD Immunity
Radiated Immunity
EFT/Burst
Surge
Conducted Immunity
Dips & Interruptions
Safety Approvals
• EN55015, class B conducted and radiated
• EN61000-3-2, class A
EN61000-3-2, class C for loads >80%
• EN61000-3-3
• EN61000-4-2, 8 kV air and 4 kV contact,
Perf Criteria A
• EN61000-4-3, level 2 Perf Criteria A
• EN61000-4-4, level 2 Perf Criteria A
• EN61000-4-5, installation class 3,
Perf Criteria A
• EN61000-4-6, level 2 Perf Criteria A
• EN61000-4-11, 30% 10 ms,
60% 100 ms, 100% 5000 ms,
Perf Criteria A, B, B
• EN61347, UL8750, CE Mark
DLG100/150: IEC60950-1, EN60950-1,
UL60950-1