DLE Datasheet, PDF (1/2 Pages) XP Power Limited – Constant Voltage AND Current Versions | |||
|
15 Watts
DLE Series
xppower.com
⢠AC Input LED Driver
⢠Constant Voltage & Current Versions
⢠High Power Factor
⢠High Efficiency
⢠Water Proof to IP67
⢠Class 2
⢠3 Year Warranty
Specification
Input
Input Voltage
Input Frequency
Input Current
Inrush Current
Power Factor
No Load Input Power
Input Protection
⢠90-264 VAC, see derating curve
⢠47-63 Hz
⢠0.25 A at 115 VAC, 0.1 A at 230 VAC
⢠15 A at 230 VAC, cold start +25 °C
⢠>0.83 at 230 VAC, full load
⢠<0.5 W max at 230 VAC
⢠Internal T1.0A/250V fuse fitted in line
Output
Output Voltage
⢠See table
Minimum Load
⢠No min load required
Start Up Delay
⢠500 ms max at 115 VAC
Hold Up Time
⢠No hold up for -A versions,
6ms min for -V versions
Line Regulation
⢠±0.5%
Load Regulation
⢠±1.0% in constant voltage mode,
±5.0% in constant current mode
Turn On Overshoot
⢠5% max
Transient Response
⢠5% max deviation, recovery to within 1%
in 10 ms for a 50% load change
Ripple & Noise
⢠1% max mV pk-pk, for - V versions
(see note 2)
Overload Protection ⢠130-160% for -V versions, auto recovery
Short Circuit Protection ⢠Trip and restart (hiccup mode)
Temperature
Coefficient
⢠0.04%/°C
General
Efficiency
Isolation
Switching Frequency
MTBF
⢠See table
⢠3750 VAC Input to Output
⢠100 kHz typical
⢠>200 kHrs to MIL-HDBK-217F at 25 °C, GB
Environmental
Operating Temperature ⢠-20 °C to +70 °C (see derating curve)
Operating Humidity ⢠5-100% RH, non-condensing
Storage Temperature ⢠-40 °C to +80 °C
Operating Altitude
⢠3000 m
Vibration
⢠10-500 Hz, 2 g, 10 mins/cycle, 6 cycles in
each of 3 axes
EMC & Safety
Emissions
Harmonic Currents
Voltage Flicker
ESD Immunity
Radiated Immunity
EFT/Burst
Surge
Conducted Immunity
Dips & Interruptions
Safety Approvals
⢠EN55015, class B conducted and radiated
⢠EN61000-3-2, class C
⢠EN61000-3-3
⢠EN61000-4-2, 8 kV air and 4 kV contact,
Perf Criteria A
⢠EN61000-4-3, level 2 Perf Criteria A
⢠EN61000-4-4, level 2 Perf Criteria A
⢠EN61000-4-5, installation class 3,
Perf Criteria B
⢠EN61000-4-6, level 2 Perf Criteria A
⢠EN61000-4-11, 100% 10 ms,
30% 200 ms, Perf Criteria B, B
⢠EN61347, UL8750, CE Mark
|
▷ |