English
Language : 

D-120A Datasheet, PDF (1/4 Pages) XP Power Limited – 120W Dual Output Switching Power Supply
60W Dual Output Switching Power Supply
D-60 series
Features :
Universal AC input/Full range
Protections:Short circuit/Over load/Over voltage
Cooling by free air convection
LED indicator for power on
Fixed switching frequency at 54KHz
2 years warranty
SPECIFICATION
MODEL
D-60A
D-60B
OUTPUT NUMBER
CH1
CH2
CH1
CH2
DC VOLTAGE
5V
12V
5V
24V
RATED CURRENT
4A
3A
3A
1.8A
CURRENT RANGE
0.3 ~ 6A
0.2 ~ 4A
0.3 ~ 6A
0.2 ~ 2.2A
RATED POWER
56W
58W
OUTPUT
RIPPLE & NOISE (max.) Note.2 75mVp-p
VOLTAGE ADJ. RANGE
CH1 : 4.75 ~ 5.5V
VOLTAGE TOLERANCE Note.3 2.0%
LINE REGULATION
0.5%
150mVp-p
6.0%
1.0%
75mVp-p
CH1 : 4.75 ~ 5.5V
2.0%
0.5%
150mVp-p
5.0%
0.5%
LOAD REGULATION
0.5%
4.0%
0.5%
4.0%
SETUP, RISE TIME
300ms, 50ms / 230VAC 800ms, 50ms / 115VAC at full load
HOLD TIME (Typ.)
80ms/230VAC 10ms/115VAC at full load
VOLTAGE RANGE
85 ~ 264VAC 120 ~ 370VDC
FREQUENCY RANGE
47 ~ 63Hz
EFFICIENCY(Typ.)
73%
76%
INPUT
AC CURRENT (Typ.)
2A/115VAC 1A/230VAC
INRUSH CURRENT (Typ.) COLD START 20A/115VAC 40A/230VAC
LEAKAGE CURRENT
<3.5mA / 240VAC
OVER LOAD
PROTECTION
OVER VOLTAGE
105 ~ 150% rated output power
Protection type : Hiccup mode, recovers automatically after fault condition is removed.
5V : 5.75 ~ 6.75V
Protection type : Hiccup mode, recovers automatically after fault condition is removed.
WORKING TEMP.
WORKING HUMIDITY
ENVIRONMENT STORAGE TEMP., HUMIDITY
TEMP. COEFFICIENT
-10 ~ +60 (Refer to output load derating curve)
20 ~ 90% RH non-condensing
-20 ~ +85 , 10 ~ 95% RH
0.03%/ (0 ~ 50 ) on +5V output
VIBRATION
SAFETY STANDARDS
WITHSTAND VOLTAGE
10 ~ 500Hz, 2G 10min./1cycle, period for 60min. each along X, Y, Z axes
UL1012, UL60950, TUV EN60950 Approved
I/P-O/P:3KVAC I/P-FG:1.5KVAC O/P-FG:0.5KVAC
SAFETY & ISOLATION RESISTANCE I/P-O/P, I/P-FG, O/P-FG:100M Ohms/500VDC
EMC
(Note 4)
EMI CONDUCTION & RADIATION Compliance to EN55022 (CISPR22) Class B
HARMONIC CURRENT
Compliance to EN61000-3-2,-3
OTHERS
NOTE
EMS IMMUNITY
Compliance to EN61000-4-2,3,4,5,6,8,11; ENV50204, EN55024, Light industry level, criteria A
MTBF
301.2K hrs min. MIL-HDBK-217F (25 )
DIMENSION
159*97*38mm (L*W*H)
PACKING
0.54Kg; 24pcs/13.8Kg/0.75CUFT
1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 of ambient temperature.
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
3. Tolerance : includes set up tolerance, line regulation and load regulation.
4. The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets
EMC directives.
File Name:D-60-SPEC 2005-09-13