English
Language : 

CU10-00 Datasheet, PDF (1/2 Pages) XP Power Limited – AC-DC Power Supplies
10-15 Watts
CU10-15 Series
xppower.com
• Low Cost
• Small Size
• PCB Mount
• 15 Watt Medical Version
• Single Output 3.3-24 V
• Peak Load Capability
• Non-standard Outputs Available
Specification
Input
Input Voltage
• 85-264 VAC (120-370 VDC)
Input Frequency
• 47-63 Hz
Input Current
• 0.13 A rms at 230 VAC (CU10)
0.20 A rms at 230 VAC (CU15)
Inrush Current
• 20 A at 115 VAC, 40 A at 230 VAC,
cold start 25 ºC
Earth Leakage Current • Class 2 (no earth)
Input Protection
• 1A fuse (CU10)
2A fuse (CU15, CU15-M)
Output
Output Voltage
• See table
Output Voltage Trim • ±5%
Initial Set Accuracy • ±1%
Minimum Load
• No minimum load required
Start Up Delay
• 1.5 s max
Start Up Rise Time
• 14 ms max
Hold Up Time
• 16 ms typical at full load and 115 VAC
Drift
• 0.6%
Line Regulation
• 0.5% max
Load Regulation
• 1.0% max 10% load to full load
Transient Response
• 4% max deviation, recovery to within 1%
within 500 µs for 25% load change
Ripple & Noise
• 1% max pk-pk (see note 1)
Overvoltage Protection • 130-150% of Vnom, recycle input to reset
Short Circuit Protection • Trip and restart (Hiccup mode)
Temperature
Coefficient
• 0.05%/˚C
General
Efficiency
Isolation
Switching Frequency
Power Density
MTBF
• See tables
• 3000 VAC Input to Output (CU10/15)
4000 VAC Input to Output (CU15-M)
• 100 kHz typical for 10 W models
67 kHz typical for 15 W models
• 2.43 W/in3 (CU10); 3.17 W/in3 (CU15)
• >500 kHrs per MIL-HDBK-217F
(15 & 24 V units >400 kHrs)
Environmental
Operating Temperature • CU10/15: 0 ˚C to +65 ˚C, derate from
full load at +45 ˚C to no load at +65 ˚C
CU15-M: 0 ˚C to +70 ˚C, derate from
full load at +50 ˚C to 50% load at +70 ˚C
Cooling
• Convection-cooled
Operating Humidity • 95% RH, non-condensing
Storage Temperature • -20 ˚C to +85 ˚C
Operating Altitude
• 3000 m
Vibration
• 10 Hz to 500 Hz, 2 g for 10 mins/cycle
60 min each cycle
EMC & Safety
Emissions
ESD Immunity
Radiated Immunity
EFT/Burst
Surge
Conducted Immunity
Dips & interruptions
Safety Approvals
• CU15-M: EN55011 Level B conducted
Others: FCC20780 Level B,
EN55022 Class B conducted
• EN61000-4-2, level 3, Perf Criteria A
• EN61000-4-3, level 3, Perf Criteria A
• EN61000-4-4, level 2, Perf Criteria A
• EN61000-4-5, level 3, Perf Criteria A
• EN61000-4-6, 10 V, Perf Criteria A
• EN61000-4-11, 30% 10 ms,
60% 1000 ms, 100% 5000 ms,
Perf Criteria A, B, B
• CU15-M: EN60601, UL2601-1, CSA22.2
No. 601.1 per cUL
Others: EN60950, UL1950, CSA22.2 No.
234 per cUL
1