English
Language : 

CPL100PD24 Datasheet, PDF (1/4 Pages) XP Power Limited – AC-DC Open Frame
AC-DC Open Frame
100-225 Watts
CPL Series
THE XPERTS IN POWER
•
Isolated Outputs
•
High Peak Current Ratings
•
Compact PCB Construction
•
Optional Remote On/Off
•
Adjustable Output Voltage
•
EN55022 Level B
•
Cover, Connector & Loom Kits Available
Specification
Input
Input Voltage
•
Input Frequency
•
Inrush Current
•
Power Factor
•
Earth Leakage
•
Current
85-264 VAC (120-370 VDC)
47-63 Hz
15/30 A at 120/230 VAC in,
100% load & 25 °C
0.99 typical at 100 VAC, 0.93 typical at
200 VAC & 100% load to IEC61000-3-2
0.75 mA max at 230 VAC 60 Hz
Output
Output Voltage
•
Output Voltage
•
Adjustment
Minimum Load
•
Start Up Time
•
Hold Up Time
•
Line Regulation
•
Load Regulation
•
Ripple & Noise
•
Overcurrent
•
Protection
Overvoltage
•
Protection
General
Efficiency
•
Isolation
•
Switching Frequency •
See Tables
±10% V1 only
No minimum load required
V1 250 ms, V2 500ms
V1 40 ms, V2 20 ms at 120 VAC
0.4% max over specified input range
0.8% max for a 100% load change
150 mV pk-pk max (0 °C to +50 °C)
>105% of rated current on V1 & >101%
of peak current on V2 auto recovery
>115% of nominal value for V1 &
115-140% of nominal value for V2
74-83% depending on specific model
3000 VAC Input to Output
2000 VAC Input to Ground
500 VAC Output to Ground
V1 to V2 100 VAC 1 min,
cut off current 100 mA,
100 VDC 10 MΩ min
80-500 kHz
Options
• Designated by the following suffixes to
the model number:
Reduce leakage current <0.1 mA ‘-G’
Remote ON/OFF ‘-R’
Cover fitted ‘-C’
Screw terminals ‘-T’
Add 4 outputs by the addition of a
DC-DC converter to the board ‘-Z’
Contact Sales Office
Environmental
Operating
•
Temperature
Storage
•
Temperature
Humidity
•
Shock
•
Vibration
•
-10 °C to +70 °C (See Derating Curve)
-20 °C to +75 °C
20-90% RH, non condensing
196.1 m/s2 (20 G), 11 ms once each
X, Y & Z axis
2 G 10-55 Hz, 3 axis
EMC & Safety
Emissions
•
ESD Susceptibility •
Radiated
•
Susceptibility
EFT/Burst
•
Surge
•
Safety Approvals
•
EN55022 Level B conducted
EN55022 Level B radiated
EN61000-4-2 Level 2 contact
Level 3 air
EN61000-4-3 Level 3
EN61000-4-4 Level 3
EN61000-4-5 Level 3 line to line
Level 4 line to ground
UL1950, C-UL, EN60950, VDE0160
•
www.xpplc.com
•
sales@xpplc.com